摘要 介绍了一种高g值冲击加速度传感器灵敏度校准的方法,即基于Hopkinson杆技术的激光多普勒干涉法,该方法能够复现冲击加速度量值,直接溯源于激光波长和时间/频率量,并使用Hopkinson杆对150000g量程的压阻式传感器进行了冲击校准,通过校准证明了该方法的可行性,而且复现方法可靠、稳定。 A laser interferometer based on a Hopkinson bar for high-g shock sensitivity calibration is described in this paper. This method can reiterate the shock sensitivity energy by tracing the laser wavelength and time/frequency directly. The shock calibration of a piezoresistive sensor with 150000 g of measuring range is completed by using Hopkinson bar method. The experimental results justifies the feasibility of this method and the retrieval method is reliable and stable.
出处 《传感器世界》 2010年第10期11-13,共3页 Sensor World
关键词 HOPKINSON杆 高g值加速度传感器 校准 激光多普勒干涉法 Hopkinson bar high-g accelerometer calibration laser Doppler interference method
  • 相关文献

参考文献5

二级参考文献21

  • 1夏源明,杨报昌.摆锤式杆杆型冲击拉伸试验装置和低温动态测试技术[J].实验力学,1989,4(1):57-66. 被引量:23
  • 2梅田章 上田和永.加速度的标准.计量管理,1991,40(2):13-19.
  • 3上田和永 梅田章.A Study on the Characterization of the Accelerometers Using Davies Bar Technique[A]..日本机械学会论文集(C编)57卷533号[C].丸善株式会社,1991.143-147.
  • 4Umeda K Umeda A.Characterization of Shock Accelerometers Using Davies Bar and Laser Interferometer.计量研究所报告,1996,45(2):1-6.
  • 5Bateman V I. Characteristics of Piezoresitive Accelerometer in Shock Environments up to 150 000 g[A]. Process 41st Annual Meeting of Institute of Environment Science [ C ]. Anaheim, CA, USA: 1995, 217~224.
  • 6Umeda K, Umeda A. Characterization of Shock Accelerometers Using Davies Bar and Laser Interferometer [ J ]. Experimental Mechanics, 1995, 35(3): 216 ~ 223.
  • 7Batemen V I. The Use of Beryllium Hopkinson Bar to Characterize a Piezoresistive Accelerometer Shock Environments [A]. Process 42nd Annual Meeting of Institute of Environment Science[C]. Orlando, FL, USA: 1996, 336 ~ 343.
  • 8Li Bin. Study on the Measurement of in-plane Displacement of Solid Surfaces by Laser Doppler Velocimetry[J]. Opt Laser Technique, 1995, 27(2): 89 ~ 93.
  • 9Wang S Y, Gao C Z, Fei P D, et al. High-G Accelerometer Dynamic Calibration by a Laser Differential Doppler Technique[J]. Rev Sci Instrum, 1996, 67(2): 2022 ~ 2025.
  • 10Umeda K. Characterization of Accelerometers in the Range Where the Vibration Method is not Effective [ A]. IMEKO world congress; From Meas to Innovation, Vol. 3 [ C ]. 1994.