摘要
文章简要介绍了广西长洲水利枢纽大型灯泡贯流式水轮发电机组发电机分块导轴瓦温差产生的原因并提出了解决方法,通过对导轴瓦支撑块厚度进行修正,发导瓦温及温差均有了明显降低,达到了预期目的。
The article discusses causes of temperature difference found at guide bearing pad of generator of large bulb tubular unit at Changzhou Hydraulic Complex and proposes solutions.To correct the thickness of guide bearing pad support lowers the temperature and temperature difference of the pad obviously.
出处
《红水河》
2010年第5期62-63,共2页
Hongshui River
关键词
贯流式机组
发导瓦
支撑厚度修正方法
长洲水利枢纽
bulb tubular unit
guide bearing pad of generator
support thickness correction method
Changzhou Hydraulic Complex