摘要
介绍承德市热电厂CG35/3.82-MX型循环流化床锅炉在运行过程中产生的出力低、运行效率下降、磨损严重、结焦、爆管等一系列问题。根据几年来的实际运行经验,经过认真分析,找出了其产生问题的原因,并对锅炉结构进行了大幅度的技术改造。改造后出力达到额定值,且运行效率大大提高,节约了能源消耗,取得了良好的经济效益和社会效益,达到了锅炉改造的目的。
This paper intreduces the problems such as under load, low efficiency, scrious erosion, slagging,tube damage, apperared in service of CG 35/3. 82-MX CFB boiler in Chendge Thermal Power Plant. Based on analysis and practical running experience for recent years, the cause is found out and boiIer structrue is retrofitted in a Iarge scale. After retrofitting, rated load is reached, efficiency increased greatly, energy consume saved, better economical and axial benefit gained and the aim of boiler retro fit arrived.
出处
《锅炉技术》
北大核心
1999年第3期30-32,共3页
Boiler Technology