期刊文献+

不同麻醉方法对腹腔镜子宫切除术患者应激反应的影响 被引量:29

原文传递
导出
摘要 目的 观察不同麻醉方法对腹腔镜子宫切除术患者应激反应的影响.方法 选择行腹腔镜子宫切除术患者45例,随机分为3组:硬膜外麻醉组(A组)、全麻组(B组)、全麻复合硬膜外阻滞组(C组)各15例,于麻醉前10 min(T0)、气腹后10 min(T1)、气腹后40 min(T2)和术后10 min(T3)四个时间点,采集静脉血测定血糖(GLU)、皮质醇(COR)和儿茶酚胺(CA)浓度,并观察PETCO2、SPO2及血流动力学变化.结果 与T0相比,A组T1时MAP、HR显著下降(P<0.05),B组T1、T2时MAP、HR、GLU、COR和CA明显升高(P<0.05),C组各时点MAP、HR、GLU、COR和CA差异无统计学意义(P>0.05);组间相比,C组各时点MAP、HR、GLU、COR和CA显著低于B组(P<0.05).结论 全麻复合硬膜外阻滞能有效地调控腹腔镜子宫切除术患者的应激反应.
出处 《中国医师杂志》 CAS 2010年第9期1208-1210,共3页 Journal of Chinese Physician
  • 相关文献

参考文献7

  • 1Ahonen J,Jokela R,Uutela K,et al.Surgical stress index reflects surgical stress in gynaecological laparoscopic day-case surgery.Br J Anaesth,2007,98(4):456-461.
  • 2Shifman EM,Butrov AV,Fedulova Ⅳ.Epidural block in anes thetic management of laparoscopic operation in gynecology.Aneste ziol Reanimatol,2007,(2):65-68.
  • 3YokoyamaM,Itano Y,KatayamaH,et al.The effects of continuous epidural anesthesia and analgesia on stress response and immune function in patients undergoing radical esophagectomy.Anesth Analg,2005,101(5):1521-1527.
  • 4穆娅玲,张宏.硬膜外麻醉与全身麻醉对妇科腹腔镜手术患者应激反应的影响[J].解放军医学杂志,2007,32(5):527-528. 被引量:12
  • 5Marana E,Scambia G,Colicci S,et al.Leptin and perioperative neuroendocrine stress response with two different anaesthetic techniques.Acta Anaesthesiol Scand,2008,52(4):541-546.
  • 6李淑琴,罗宝蓉,王保国.末梢灌注指数与全身麻醉患者血流动力学及儿茶酚胺的相关性[J].中华医学杂志,2008,88(17):1177-1180. 被引量:24
  • 7Kuramochi K,OsugaY,YanoT,et al.Usefulness of epidural anesthesia in gynecologic laparoscopic surgery forinfertility in comparison to general anesthesia.Surg Endosc,2004,18(5):847-851.

二级参考文献16

  • 1穆娅玲,王明军,张宏.全身麻醉与硬膜外麻醉在妇科腹腔镜手术中对呼吸、循环的影响[J].解放军医学杂志,2005,30(8):750-751. 被引量:17
  • 2罗宝蓉,康孝荣,王保国.末梢灌注指数监测全麻患者应激反应的评价[J].中华麻醉学杂志,2007,27(2):117-119. 被引量:15
  • 3Seitsonen ER, Korhonen IK, Gils MJ, et al. EEG spectral entropy, heart rate, photoplethysmography and motor responses to skin incision during sevoflurane anaesthesia. Acta Anaesthesiol Stand ,2005,49 : 284-292.
  • 4Luginbuhl M, Reichlin F, Sigurdsson GH,et al. Prediction of the haemodynamic response to tracheal intubation: comparison of laser-Doppler skin vasomotor reflex and pulse wave reflex. Br J Anaesth. 2002, 89: 389-397.
  • 5Khan F, Spence VA, Wilson SB, et al. Quantification of sympathetic vascular responses in skin by laser Doppler flowmetry. Int J Micrecirc Clin Exp, 1991,10 : 145-153.
  • 6Mangano DT, Layug EL, Wallace A,et al. Effect of atenolol on mortality and cardiovascular morbidity after noncardiac surgery. Multicenter Study of Perioperative Ischemia Research Group. N Engl J Med, 1996, 335 : 1713-1720.
  • 7Shimoda O, Ikuta Y, Sakamoto M, et al. Skin vasomotor reflex predicts circulatory response to laryngoscopy and intubation. Anesthesiology, 1998, 88:297-304.
  • 8Debroucker T, Wilier JC, Bergeret S. The nociceptive flexion reflex in human: a specific and objective correlate of experiment pain// Chapman CR, Loeser JD. Issues in pain measurement. New York : Raven Press, 1989 : 337-352.
  • 9Kano T, Shimoda O, Higashi K, et al. Fundamental patterns and characteristics of the laser-Doppler skin blood flow waves recorded from the finger or toe. J Auton Nerv Syst ,1993 ,45 :191-199.
  • 10Oczenski W, Fitzgerald RD. Hemodynamic and catecholamine stress responses to insertion of the combitube, laryngeal mask airway or tracheali intubation. Anesth Analg, 2000, 90:231-232.

共引文献31

同被引文献174

二级引证文献158

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部