期刊文献+

IEC 61000-4-2中ESD间接放电实验一致性研究 被引量:1

Study on Consistency in Indirect Application for ESD Test Defined by IEC 61000-4-2
在线阅读 下载PDF
导出
摘要 国际电工委员会标准IEC 61000-4-2:2001修改了对位于受试设备下方的水平耦合板施加放电的试验方法。按照新的试验方法对3种不同厂商生产的静电放电模拟器在水平耦合板上产生的电场和磁场的一致性进行了研究比较。实验结果表明,距离放电点较近时,不同模拟器之间产生的场的差异很大,而距离放电点较远时,不同模拟器之间的差异变小,可以通过增大放电间距来改善不同模拟器之间的一致性;提高放电电压,可使不同模拟器之间的差异进一步减少。 The method of indirect ESD testing in IEC61000-4-2:2001 was changed by IEC.The consistency of the distribution of E-fields and H-fields on the Horizontal Coupling Plane(HCP) of three different simulators was analyzed,according to the new method.The results showed that at the near point from the centre point of the front edge of HCP,the field differences of simulators are large;at the far point,the field differences of simulators are small;increasing the discharge distance properly can reduce the difference in test results among different brand simulators;large discharge voltage can also improve the field consistency of the different simulators.
出处 《装备环境工程》 CAS 2010年第5期160-164,共5页 Equipment Environmental Engineering
关键词 静电放电 间接放电 水平耦合板 ESD模拟器 electrostatic discharge indirect application horizontal coupling plane ESD simulator
  • 相关文献

参考文献5

二级参考文献15

  • 1张希军,武占成,阮晓芬,王书平.静电放电模拟器辐照效应实验研究[J].军械工程学院学报,2003,15(3):7-10. 被引量:2
  • 2[1]刘尚合,魏光辉,刘直承,等.静电理论与防护.北京:兵器工业出版社,1 997.
  • 3[4]Wilson P F,M a M T.Fields radiated by elect ro static discharges.IEEE Trans.on EMC,1991,33 (1):10~13.
  • 4[6]David Pommerenke and Martin Aidam.ESD waveform Calculation,Fields and Current of Human and Simulator ESD.Journal of Electrostatics,1996 (38):33~51.
  • 5魏明,刘尚合.LEMP对数字电路的作用机理研究[J].军械工程学院学报,2001,16(4):1-4.
  • 6[3]Graziano Cerri, Simona Chiaradini, Simone Costantini,et al. Theoretical and experimental characterization of transient electromagnetic fields radiated by ESD currents[J]. IEEE Transactions on EMC, 2002, 44(2): 139- 146.
  • 7[5]Leuchtmann P, Sroka J Transient field simulator of electrostatic discharge (ESD) in the calibration setup (acc.IEC61000-4-2)[Z]. IEEE International Symposium on Electromagnetic Compatibility, Zurich, 2000.
  • 8Kurt H, Heinrich R, Ulrich H.Calibration of electrostatic discharge generators and results of an international comparison[J].IEEE Trans on Instrumentation and Measurement, 2001, 50(2): 414-418.
  • 9Graziano C, Simona Ch, Simone Co. Theoretical and experimental characterization of transient electromagnetic fields radiated by electromagnetic fields radiated by electrostatic discharge (ESD) currents[J].IEEE Trans on Electromagnetic Compatibility, 2002, 44(1):139-147.
  • 10Graziano C, Francesco C, Luca F, et al. Measurement of magnetic fields radiated from ESD using field sensors[J].IEEE Trans on Electromagnetic Compatibility, 2001, 43(2):187-196.

共引文献36

同被引文献22

  • 1贺其元,刘尚合,孙国至,陈京平.ESD发生器开关动作对抗扰度试验的影响[J].高电压技术,2007,33(6):93-96. 被引量:5
  • 2Ramachandran C, Pommerenke D , Wang Kai, et al. Charac- terization of human metal ESD reference discharge event and correlation of generator parameters to failure levels-part I: ref- erence event[J]. IEEE Transactions on Electromagnetic Com- patibility, 2004, 46(4):498-504.
  • 3Wang Kai, Pommerenke D, Ramachandran C, et al. Character- ization of human metal ESD reference discharge event and corre-lation of generator parameters to failure levels part II: Correla- tion of generator parameters to failure levels[J]. IEEE Transac tions on Electromagnetic Compatibility, 2004, 46(4) :505-511.
  • 4Jayong K, Qing C, Kai Wang, et al. Correlation between EUT failure levels and ESD generator parameters[J]. IEEE Transac- tions on Electromagnetic Compatibility, 2008, 50(4): 794-801.
  • 5Vladislav A, Vashchenko A S. ESD design for analog circuits [M]. New York, USA: Springer Science and Business Media, 2010 : 398-400.
  • 6Smedes T. ESD testing of devices, ICs and systems[J]. Microe lectronics Reliability, 2009, 48 (9/11): 941-945.
  • 7IEC 61000 4-2 Electromagnetic compatibility (EMC), part 4-2: testing and measurement techniques, section 2~ electrostatic discharge immunity test [S], 2001.
  • 8Wilson P F, Ma M T. Fields radiated by electrostatic discharges [J]. IEEE Transactions on Electromagnetic Compatibility, 1991, 33 (1): 10-18.
  • 9Fotis G P, Rapanakis A G, Gonos I F, et al. Measurement of the magnetic field radiating by electrostatic discharges during the verification of the ESD generators[J]. Measurement, 2007, 40 (4): 428-436.
  • 10Fotis G P, Christodoulou C A, Pippis C D, et al. Measure- ment of the electromagnetic field radiating by commercial ESD generators with the Pellegrini target on insulating material[J]. Measurement, 2009, 42(7):1073-1081.

引证文献1

二级引证文献43

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部