期刊文献+

并网逆变器死区补偿研究

Study on Compensating Dead-Time of Grid Connected Inverter
在线阅读 下载PDF
导出
摘要 为解决并网逆变器存在的死区效应,介绍了一种并网逆变器的死区补偿方法。分析了并网逆变器死区效应产生的原因,提出用带通滤波器滤除电流信号的纹波和干扰,根据滤波后的电流信号极性来确定PWM驱动信号的补偿量。给出了一种基于带通滤波器的死区补偿算法。试验结果表明,该算法能有效地补偿并网逆变器的死区效应,消除输出电流的交越失真。 In order to eliminate dead-time effect of the grid inverter,a dead-time compensation algorithm was introduced.The reason was analyzed why dead-time effect of the grid inverter occured,an algorithm was presented that a band-pass filter was used to eliminate harmonics and jamming among the current signal and according to polarity of the filtered current signal,the compensation value of the PWM driving signal could be confirmed.Eventually a dead-time compensation algorithm based on band-pass filter was proposed.Experimental results showed that the algorithm was able to effectively compensate dead-time effect of the grid inverter and eliminate crossover distortion of the output current.
作者 吴华波
机构地区 广东嘉应学院
出处 《低压电器》 北大核心 2010年第17期36-39,共4页 Low Voltage Apparatus
关键词 死区效应 死区补偿 带通滤波器 交越失真 dead-time effect dead-time compensation band-pass filter crossover distortion