摘要 在神光Ⅲ原型装置上,利用8束激光单端驱动半腔靶实验研究了黑腔等离子体聚心时间.通过改变腔底结构建立了4种黑腔辐射源,比较了等离子体径向的聚心时间与黑腔辐射温度的变化关系.径向聚心时间和辐射温度分别由X射线分幅相机和软X射线能谱仪给出.研究发现,4种辐射源的等离子体径向聚心时间与辐射温度之间存在正比关系,聚心时间随辐射温度升高而延后。 Plasma convergence time of half-hohlraum target with single-end drive by 8 bundled lasers are researched on SG-III prototype laser facility.Four radiation sources were established by changing the structure of target bottom.The relation between plasma radial convergence time obtained by x-ray framing camera and radiation temperature from soft x-ray spectrometer have been investigated.The results showed that plasma radial convergence time is directly proportional to radiation temperatures on different structures of target bottom,which lengthens as radiation temperature increases.
出处 《物理学报》 SCIE EI CAS CSCD 北大核心 2010年第10期7170-7174,共5页 Acta Physica Sinica
基金 国家重点基础研究发展计划(批准号:2007CB814802)资助的课题~~
关键词 聚心时间 辐射温度 半腔靶 X射线分幅相机 convergence time radiation temperature half-hohlraum target x-ray framing camera
  • 相关文献

参考文献14

  • 1Drake R P 2006 High Energy Density Physics (New York: Springer) p335.
  • 2Campbell E M, Hogan W J 1999 Plasma Phys. Contr. Fusion 41 B39.
  • 3Lindl J D 1995 Phys. Plasmas 2 3933.
  • 4Lindl J D, Amendt P, Berger R L, Glendinning S G, Glenzer S H, Haan S W, Kauffman R L, Landen 0 L, Suter L J 2004 Phys. Plasmas 11 339.
  • 5Cavailler C 2005 Plasma Phys. Contr. Fusion 47 B389.
  • 6Rothman S D, Evans A M, Horsfield C J, Graham P, Thomas B R 2002 Phys. Plasmas 9 1721.
  • 7Chang T Q, Wang G Y 2001 Phys. Plasmas 8 1659.
  • 8李三伟 易荣清 蒋小华 何小安 崔延莉 刘永刚 丁永坤 刘慎业 蓝可 李永升 吴畅书 古培俊 裴文兵 贺贤土.物理学报,2009,58:3255-3255.
  • 9孙可熙 江少恩 易荣清 崔延莉 丁永坤 刘慎业.物理学报,2006,55:68-68.
  • 10曹柱荣,丁永坤,张海鹰,白晓红,刘百玉,白永林.X射线分幅相机真空弧放电损害研究[J].强激光与粒子束,2007,19(2):321-326. 被引量:7

二级参考文献15

  • 1成金秀,温天舒,朱宗元,杨存榜,常增虎,山冰,侯继东.MCP选通X射线皮秒分幅相机在ICF中的应用[J].强激光与粒子束,1996,8(1):73-77. 被引量:10
  • 2盛亮,魏福利,吕敏,王奎禄,邱爱慈,黑东炜,邱孟通,袁媛,赵吉祯,王培伟.丝阵负载Z箍缩可见光图像诊断系统[J].强激光与粒子束,2006,18(8):1396-1400. 被引量:14
  • 3Bradley D K,Bell P M,Landen O L,et al.Development and characterization of a pair of 30~40 ps X-ray framing cameras[J].Rev Sci Instrum,1995,66:716-718.
  • 4Robey H F,Budil K S,Remington B A.Spatial resolution of gated X-ray pinhole cameras[J].Rev Sci Instrum,1997,68:792-795.
  • 5Bradley D K,Bell P M,Kilkenny J D,et al.High-speed gated X-ray imaging for ICF target experiments[J].Rev Sci Instrum,1992,63:4813-4817.
  • 6Oertel J A,Archuleta T N,Schrank L S.The large format X-ray imager[J].Rev Sci Instrum,2000,72:701-704.
  • 7Pawley C J,Deniz A V.Improved measurements of noise and resolution of X-ray framing cameras at 1~2 keV[J].Rev Sci Instrum,2000,71:1286-1295.
  • 8Marshall F,Oertel J A.A framed monochromatic X-ray microscope for ICF[J].Rev Sci Instrum,1997,68:735-737.
  • 9莫纯昌,陈国平.电真空工艺[M].北京:国防工业出版社,1984:222-223.
  • 10Okano K,Hoshina K,Iida M.Fabrication of a diamond field emitter array[J].Appl Phys Lett,1994,64:2742-2744.

共引文献24

同被引文献19

引证文献2

二级引证文献10

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部