摘要
虽然正序故障分量方向元件原理简单,与其它方向元件相比具有自已独特的优越性。但在特殊的条件和环境下,也存在一定的问题。本文在讨论正序故障分量方向元件的原理基础上,针对其存在的几个特殊问题,进行了分析讨论,并提出了新的观点和看法。
Although directional relay based on positive sequence fault components to other directional relay, they have some problems under particular conditions and circumstances too. This article elucidates a few particular problems based on discussing the principle of directional relay based on positive sequence fault components and proposed some new viewpoints.
出处
《继电器》
CSCD
1999年第3期16-19,共4页
Relay
关键词
正序故障分量
方向元件
继电保护
电力系统
positive sequence fault components
directional relay
particular problems