摘要 分析了蓝宝石光纤温度传感器测试系统组成及工作原理,由于黑体腔膜层内外表面存在较大温差,使得该系统测出的被测物温度存在一定误差.为了解决这一问题,运用分离变量法从黑体腔内表面温度外推出黑体腔外表面温度,降低了测试对传感器的性能要求,实验验证了该方法的可行性,提高了蓝宝石光纤黑体腔温度传感器的测温精度. The composition and the working principle of the test system for the sapphire optical fiber temperature sensor were analyzed. As there is a big temperature difference between the inner and outside surface of black body cavity, so the error of temperature of the measured object is presented. To solve this problem, a process of separating variables was used to derive the outer surface temperature of black body cavity from the inner surface temperature of the blackbody cavity, which further improved the performance of the sensor required by test. The experiment tested the feasibility of this method, and the measurement accuracy of the sapphire optical fiber blackbody cavity temperature sensor was improved.
出处 《光电技术应用》 2010年第4期9-11,41,共4页 Electro-Optic Technology Application
基金 国家部委基础科研项目资助 电子测试技术国家级重点实验室资助项目(9140C1204040705) 中北大学校基金资助项目
关键词 黑体腔 外推法 分离变量法 blackbody cavity extrapolation separation of variables
  • 相关文献

参考文献3

  • 1Rumsey C B.Techniques and Instrumentation Associated with Rocket Model Heat-Transfer Investigation.Report AGARD[R] ,1997,8.
  • 2F Kreith,M S Bohn.Principles of Heat Transfer[M].4th Ed.Harper & Row,1986:136-137.
  • 3郝晓剑 ,孙伟 ,周汉昌 ,赵宇 .蓝宝石光纤黑体腔高温计[J].应用基础与工程科学学报,2004,12(2):218-223. 被引量:18