摘要
该文通过对某建筑场地地下水压力的监测与渗流分析,确定了基底和地下室外墙的水压力值,解决了抗浮验算中的地下水压力问题,其结果对类似的工程具有一定的借鉴作用。
The groundwater pressure on the bottom of the foundation and on the external wall of basement are determined by the methods of monitoring and seepage analysis of the groundwater pressure at a certain construction site, and anti -buoy- ance problem of groundwater has been solved . The results are available for reference to similar engineering projects.
出处
《勘察科学技术》
1999年第2期3-5,共3页
Site Investigation Science and Technology
关键词
建筑场地
抗浮验算
地下水压力
渗流分析
基础
construction site
anti - buoyance problem
groundwater pressure
seepage analysis