期刊文献+

StarClose血管缝合器在冠状动脉介入术中临床应用的评价 被引量:4

Clinical evaluation of StarClose vascular closure device in percutaneous coronary intervention
原文传递
导出
摘要 目的评价StarClose血管缝合器在冠状动脉介入术中使用的安全性和有效性。方法 203例行冠状动脉介入治疗患者,其中男性110例,女性93例;年龄44~75岁,平均年龄57.92岁。依据股动脉穿刺点止血方法分为StarClose血管缝合器组(n=101)和人工压迫止血组(n=102),分别记录两组患者股动脉止血时间、下肢制动时间和相关并发症。结果缝合器组的止血时间、下肢制动时间及并发症发生率明显低于人工压迫组(P<0.05)。结论 StarClose血管缝合器应用于临床具有良好的安全性和有效性。 Objective To evaluate the efficacy and safety of StarClose vascular closure device in percutaneous coronary intervention.Methods A total of 203 patients were performed percutaneous coronary intervention,male 110,female 93,aged 44 75 years,mean age 57.92 years.StarClose vascular closure device was used in 101 patients as suture group and manual compression hemostasis was adopted in 102 patients as manual compression group.The hemostasis time,immobilization time of lower extremities,and related complications in 2 groups were recorded respectively.Results The hemostasis time,immobilization time and complication rate were significantly lower in suture group than that in manual compression group(P 0.05).Conclusion It is demonstrated that performing with StarClose vascular closure device has a good efficacy and safety in operation of percutaneous coronary intervention.
出处 《生物医学工程与临床》 CAS 2010年第5期416-418,共3页 Biomedical Engineering and Clinical Medicine
关键词 冠状动脉介入术 StarClose血管缝合器 人工压迫 止血时间 制动时间 percutaneous coronary intervention StarClose vascular closure device manual compression hemostasis time immobilization time
  • 相关文献

参考文献7

  • 1Ratnam LA,Raja J,Munneke GJ,et al.Prospective nonrandomi-zed trial of manual compression and Angio-Seal and StarClose arterial closure devices in common femoral punctures[J].Cardio-vasc Intervent Radiol,2007,30(2):182-188.
  • 2Ikeno F,Sadoughi MA,Lyons JK,et al.Arteriotomy closure dev-ice application following percutaneous coronary intervention may prevent bleeding complications in patients with acute myo-cardial infarction[J].Int J Cardiol,2007,117(1):131-132.
  • 3Nikolsky E,Mehran R,Halkin A,et al.Vascular complications associated with arteriotomy closure devices in patients under-going percutaneous coronary procedures:a meta-analysis[J].J Am Coll Cardiol,2004,44(6):1200-1209.
  • 4Deuling JH,Vermeulen RP,Anthonio RA,et al.Closure of the femoral artery after cardiac catheterization:a comparison of An-gio-Seal,StarClose,and manual compression[J].Catheter Card-iovasc Interv,2008,71(4):518-523.
  • 5Engelbert TL,Scholten A,Thompson K,et al.Early ambulation after percutaneous femoral access with use of closure devices and hemostatic agents[J].Ann Vasc Surg,2010,24(4):518-523.
  • 6Imam A,Carter RM,Phillips-Hughes J,et al.StarClose vascular closure device:prospective study on 222 deployments in an in-terventional radiology practice[J].Cardiovasc Intervent Radiol,2007,30(4):738-742.
  • 7吴玉辉,江蕊,解见业.冠状动脉造影术后血管缝合器应用的临床评价[J].青岛大学医学院学报,2009,45(1):54-56. 被引量:2

二级参考文献12

  • 1侯磊,周可,徐建刚,李伟明,陈艳清,徐亚伟.冠状动脉造影和治疗术后应用血管缝合器的研究[J].中华心血管病杂志,2005,33(1):65-65. 被引量:7
  • 2彭文华,王勇,曾玉杰,李宪伦,柯元南.临床论著经皮冠状动脉介入治疗后应用第三代PerClose血管缝合器的初步[J].中日友好医院学报,2005,19(5):259-261. 被引量:2
  • 3HEINZEN M P, STIRAUER B E. Peripheral arterial compli cations after heart catheterization[J]. Herz, 1998,23 - 4 20.
  • 4NASSER T K, MOHLER E R, WILENSKY R L, et al. Peripheral vascular complications following coronary interven- tional procedures[J]. Clin Cardiol, 1995,18(11) :609-614.
  • 5KORNOWSKI R, BRANDES S, TEPLITSKY I, et al. Safety and efficacy of a 6 French perclose arterial sutring device following percutaneous coronary intervertions: a pilot evalution [J]. J Invasive Cardiol, 2002,14 :741-745.
  • 6BLANE R, MOUNAYER C, PIOTIN M, et al. Hemostatic closure device after carotid punture for stent and coil placement in an intracranial aneurysm: technical nate[J]. AJNR Am J Euroradiol, 2002,23(6) :978-981.
  • 7SHRAKE K L. Comparison of major complication rates associated with four methods of arterial closure[J]. Am J Cardiol, 2000, 85 : 1024-1025.
  • 8DANGAS G, MEHRAN R, KOKOLIS S, et al. Vascular complications after pereutaneous coronary interventions fol- lowing hemostasis with manualcompression versus arteriotomy closure devicesl[J]. J Am Coll Cardiol, 2001,38(3):638- 641.
  • 9KORENY M, RIEDMULLER E, NIKFARDJAM M, et al. Arterial puncture dosing devices compared with standard man ual compression after cardiac catheterrization: systematic review and meta analysis[J]. JAMA, 2004,291(3):350-371.
  • 10NASU K, T SUCHIKANE E, SUMITSUJI S, et al. The safety and eficacy of "pre-closure" utilizing the closure suture- mediated vascular closure device for achievement of hemostasis in patients following coronary interventions: results of the second perclose accelerated ambulation and discharge (paradise Ⅱ ) trial[J]. J Invasive Cardiol, 2005,17(1):30-33.