摘要 便携式COD快速测定仪专用氧化剂是影响测定COD准确度的关键,其中重铬酸钾含量对实验过程中的氧化效率有较大影响,含量太低时,氧化过程不充分导致测定结果偏低;含量过高,造成样品颜色被氧化剂自身色度掩盖,使得反应后吸光度值变化不明显,测定COD浓度较低的水样时吸光度值误差较大。通过正交实验对COD专用氧化剂进行配方改进,优化筛选出的COD专用氧化剂应用于现场实时监测,测定的COD准确度达到实验室要求。 Special oxidants of COD rapid detectors are the key to the accuracy of COD testing.The content of potassium dichromate can largely affect the oxidation efficiency in the experiments.If the content of potassium dichromate is too low,the inadequate oxidation process causes the testing results low.If the content is too high,the color of the oxidants covers up the sample color,resulting in a little change in absorbance values and a relatively large deviation when testing water samples with lower COD concentration.Through orthogonal pairs to improve the COD specific oxidants,the optimized COD specific oxidants can be used in on-site monitoring,and the measured COD can achieve laboratory accuracy requirements.
出处 《油气田环境保护》 CAS 2010年第3期6-8,共3页 Environmental Protection of Oil & Gas Fields
关键词 COD 氧化剂 准确度 优化筛选 COD oxidants accuracy optimal filtration
  • 相关文献

参考文献6

二级参考文献16

  • 1孟爱华,汪云,王秀.使用MnSO4作重铬酸钾法测定COD代用催化剂的机理探讨[J].山东工业大学学报,1996,26(2):101-103. 被引量:8
  • 2中国环境监测总站.环境水质监测质量保证手册(第二版)[M].北京:化学工业出版社,1994.225-226.
  • 3国家环保局.水和废水监测分析方法[M].中国环境科学出版社,1997..
  • 4张世森.环境监测技术(第二版)[M].北京:高等教育出版社,1996.571-572.
  • 5Kate Peter.Wastewater in ozone test continuous rapid COD measurement[J].Chem-Anagon Verfahren,1991,23(5):52.
  • 6[3]武汉大学.分析化学(第3版)[M].北京:高等教育出版社,1998.
  • 7[1]盛骤,谢式千,潘承毅.概率论与数理统计.北京:高等教育出版社.1995.
  • 8国家环保总局.水和废水监测分析方法(第3版)[M].北京:中国环境科学出版社,1989..
  • 9中国环境监测总站.环境水质监测质量保证手册(第二版)[M].北京:化学工业出版社,1994..
  • 10国家环保局.水和废水监测分析方法[M].北京:中国环境科学出版社,1997.326.