摘要
对马钢2500m^3高炉冷却壁损坏情况进行了调查,并对破损原因进行了分析。针对不同的破损情况,采取不同护炉保产措施,以达到高炉长寿的目的。
The conditions of cooling stave damaged at Masteel's 2 500 m3 BF were investigated, and the causes were analysed.According to different damaged situations, some measures were adopted in order to prolong blast furnace life.
出处
《炼铁》
北大核心
1999年第3期9-12,共4页
Ironmaking
关键词
高炉
冷却壁
破损分析
blast furnace cooling stave damage analysis