摘要 分析了静止同步发生器(static synchronous compensator,STATCOM)与静止无功补偿装置(static var compensation,SVC)的工作特性与基本原理;对STATCOM与SVC的性能从多角度进行了比较。得出STATCOM具有响应速度快、控制方法先进、谐波含量少等优点,并对实际应用做了分析和介绍。指出了STATCOM是无功补偿与谐波抑制综合技术的发展方向,也是电能质量研究的重点内容。 The operation characteristics and basic principle between static synchronous compensator(STATCOM)and static var compensation(SVC)are analyzed in this paper.The performance of STATCOM and SVC are compared from different aspects.It is concluded that STATCOM has advantages,such as fast response,advanced control method,less harmonic content etc.Its actual application is analyzed and introduced,and it is pointed out that STATCOM not only is the development direction of combination technology of reactive compensation and harmonic suppression,but also is research key contents of power quality.
出处 《电力电容器与无功补偿》 2010年第4期1-4,共4页 Power Capacitor & Reactive Power Compensation
关键词 静止同步发生器(STATCOM) 静止无功补偿装置(SVC) 无功补偿 谐波抑制 static synchronous compensator(STATCOM) static var compensation(SVC) reactive power compensation harmonic suppression