摘要
对空调在使用过程中所出现的回液及液态制冷剂进入压缩机的现象进行了分析并指出了其危害性;同时提出了针对性的改进措施,对空调气液分离器的应用及优化设计,尤其是回油孔的设计进行了详细的阐述。实践证明合理地设计及应用气液分离器,对提高空调产品的可靠性具有十分重要的意义。
This paper analyzed the phenomenon of liquid refrigerant entering the compressor in the process of air conditioner using and pointed its harm. At the same time, the improved method was put forward and the application and optimization of air conditioning gas-liquid separator were expounded, especially the design of the oil return hole. Practice proved that design and apply the gas-liquid separator legitimately have a very important signification to improve the reliability of air conditioner product.
出处
《制冷空调与电力机械》
2010年第4期6-10,共5页
Refrigeration Air Conditioning & Electric Power Machinery
关键词
回液
气液分离器
应用及优化设计
研究
liquid return
gas-liquid separator
application and optimization
research