自然心率下40层螺旋CT在冠状动脉成像中的应用 被引量:3

Application of 40-slice spiral CT coronary angiography with nature heart rate
暂未订购
导出
摘要 目的:评价自然心率下40层螺旋CT(Philips Brilliance40)冠状动脉成像的效果。方法:应用Philips Brilliance40CT对219例疑诊冠心病患者自然心率下行前瞻性心电门控平扫和回顾性心电门控增强扫描,对扫描数据在工作站行VR、CPR、MIP等后处理,得到冠状动脉主要分支图像,并根据图像质量评分。实际扫描心率范围52~119/min,以10/min为间隔,按不同扫描心率将图像分成6组。各组间图像质量采用Kruskal-Wallis单向评秩方差分析统计学处理,分析组间图像质量是否一致。结果:在50~100/min心率范围内各心率段图像质量差异无统计学意义。扫描心率>100/min图像质量下降,造成图像质量与其他组间对比差异具有统计学意义。结论:Philips Brilliance40CT扫描技术的提高使其冠状动脉成像图像质量提升,适用心率范围加大,可在自然心率下完成MSCT冠状动脉成像检查,得到较高质量的冠状动脉图像。 Objective:To assess the effect of 40-slice spiral CT (Philips Brilliance 40) coronary angiography with nature heart rate. Methods:219 patients underwent prospective electrocardiogram-gated plain and retrospective electrocardiogram-gated enhanced scanning with nature heart rate. VR,MIP,and CPR reconstructions were made using extended brilliance workspace. The images quality was compared by different heart rate teams after the images were degreed by quality. Results:With heart rate of 50~100 beats per minute,the difference of images quality among different heart rate teams was not significant. Images quality descend with heart rate 〉100 beats per minute. Conclusion:Philips Brilliance 40 CT scanning technology improves image quality of coronary angiography,increases heart rate range,40-slice spiral CT coronary angiography can be completed with nature heart rate,get high quality images of coronary.
作者 杜国新 赵琦
出处 《中国当代医药》 2010年第23期80-82,共3页 China Modern Medicine
关键词 自然心率 体层摄影术 X线计算机 冠状血管造影术 Nature heart rate Tomography X-ray computer Coronary angiography
  • 相关文献

参考文献8

  • 1薛华丹,张竹花,金征宇,林松柏,赵文敏,张立仁,张抒扬.多层螺旋CT冠脉造影的标准体位[J].中国医学影像学杂志,2004,12(5):324-327. 被引量:10
  • 2Detre KM,Wright E,Murphy ML,et al.Observer agreement in evaluating coronary angiograms[J].Circulation,1975,52(6):979-86.
  • 3姚泰,吴博威.生理学[M].6版.人民卫生出版社,2003:89-92,130-131.
  • 4Becker CR,Knez A,Leber A,et al.Initial experiences with multi-slice detector spiral CT in diagnosis of arteriosclerosis of coronary vessels[J].Radiology,2000,40(2):118-122.
  • 5Neman K,Cademartiri F,Lane GE,et al.Reliable noninvasive coronary angiography with fast submillimeter multi-slice spiral computed tomography[J].Circulation,2002,106(24):2051-2054.
  • 6Neman K,Rensing BJ,Van Ceurs RJ,et al.Noninvasive coronary angiography with multislice spiral computed tomography:Impact of heart rate[J].Heart,2002,88(5):470-474.
  • 7Flohr T,Ohnesorge B.Heart rate adaptive optimization of spatial and temporal resolution for electrocardiogram-gated multislice spiral CT of the heart[J].J Comput Assist Tomogr,2001,25(6):907-923.
  • 8肖格林,黄正林,余水全,张华堂,付万红.心率及重建时相对MSCT冠状动脉造影图像质量的影响[J].华夏医学,2005,18(3):319-321. 被引量:7

二级参考文献10

  • 1张竹花 金征宇 李冬晶 等.多层螺旋CT冠状动脉成像研究[J].中华放射学杂志,2003,37(9):147-147.
  • 2Vogl TJ,Abolmaali ND,Diebold T,et al.Techniques for the detection of coronary atherosclerosis: multi-detector row CT coronary angiography. Radiology, 2002,223:212
  • 3Schroeder S,Kopp AF,Baumbach A,et al.Noninvasive detection of coronary lesions by multislice computed tomography: results of the new age pilot trial. Cathet Cardiovasc Intervent,2001,53:352
  • 4Achenbach S,Ulzheimer S,Baum U,et al. Noninvasive coronary angiography by retro- spectively ECG-gated multislice spiral CT.Circulation,2000,102:2823
  • 5Ennedy JW.Complications associated with cardiac catheterization and angiography[J].Cath Cardiovasc Diagn,1982,8:5-11.
  • 6Hong C, Becker CR,Huber A,et al. ECG-gated reconstructed multi-detecter row CT coronary angiography:effect of varying trigger delay on image quality[J]. Radiology,2001,220:712-717.
  • 7Nieman K,Creasing BJ,Van Geuns RJ,et al.Uesfulness of multislice computed tomography fordetedcting obstructive coronary disease[J].Am J Cardionl,2002,89:913-918.
  • 8Kopp AF, Schroder S, Kuettner A, et al.Coronary arteries:retrospectively ECG-gated multi-detecter row CT angiography with selective optimization of the imagine reconstruction window[J].Radiology,2001,221:683-688.
  • 9Hoffman MBM, Wickline SA, Lorenz CH. Quantification of in-planemotion of the coronary arteries during the cardiac cycle:Implications for acquisition window duration for MR flow quantification[J].J Magn Reson Imaging,1998,8:568-576.
  • 10萧毅,田建明,王培军,秦永文,薛宏,李晓兵,王敏杰,左长京,曾浩,崔恒武.多层螺旋CT冠状动脉造影的扫描技术及临床应用[J].中华放射学杂志,2002,36(4):357-361. 被引量:144