期刊文献+

PK301故障原因分析及改进措施 被引量:2

Failure analysis and amelioration steps of PK301
原文传递
导出
摘要 聚丙烯装置的关键设备PK301频繁故障停车,通过分析各类故障发生原因,着重解决气相带粉问题和分液罐除沫器结构,通过运行考核,机组实现了长周期运转实现长周期运行14个月不大修。 PK301,the key equipment of PP plant shuts down frequently because of different failures.We solved the main failures of gas phase with powders and knockout drum defoamer structure defect by analyzing reasons of different failures.The machine system achieved long period operation after running test.
出处 《计算机与应用化学》 CAS CSCD 北大核心 2010年第8期1148-1150,共3页 Computers and Applied Chemistry
关键词 聚丙烯 压缩机 故障 改进措施 polypropylene compressor failures improvement
  • 相关文献

参考文献2

  • 1Deng Yanqin. Reason analysis of powder schlepping and strategy of PK301 in PP plant. Petro-Chemical of Jiangxi, 2005, 17(3).
  • 2Oan Yongqiang, Liu Xiaokun. Maintenance and failure strategy of PK301 in PP plant. Petro-Chemical Equipment, 2009, (38):Supplement.