期刊文献+

用于遥感测温的双通道红外辐射计 被引量:3

A Double-Channel Infrared Radiometer for Remote Sensing Temperature
在线阅读 下载PDF
导出
摘要 本文介绍了一种用于遥感温度测量的、且与目前大多数星载红外遥感器波段相一致的双通道红外辐射计。该辐射计采用碲镉汞做为探测器。它可用于温度测量,其同步测量数据可用于星载红外遥感器的定标和数据的真实性检验。本文介绍了总体方案、精度计算及光、机、电和数据处理等部分的设计方法。 A double-channel infrared radiometer for remote sensing temperature is provided.The radiometer has the same wave length bands with the most of the satellite infrared remote sensors,and uses HgCdTe as the detector.Besides measuring temperature,its synchronous data can be used to calibrat/validat the satellite infrared remote sensing data.The overall scheme of the instrument and accuracy calculation are introduced in this paper.The design procedures of optical,mechanistic and electrical and data processing are also discussed.
作者 王项南
出处 《海洋技术》 1999年第1期28-34,共7页 Ocean Technology
关键词 遥感 测温 双通道 红外辐射计 海洋环境监测 infrared optics,remote sensing,radiometer
  • 相关文献

参考文献3

  • 1杨宜和.红外系统[M].国防工业出版社,..
  • 2(美)P.W克罗.红外技术基础[M].,..
  • 3(英)L.M.比伯曼.光电调制中的调制盘[M].,..

同被引文献25

  • 1郭文红.红外测温仪的主要工作原理及应用实践[J].仪器仪表用户,2024,31(5):104-106. 被引量:3
  • 2董仁杰,李铜基,陈清莲,任洪启.星载红外辐射计海上辐射校正方法研究[J].海洋技术,2006,25(2):73-77. 被引量:4
  • 3朱启海,李宪圣,任建伟,赵长明,景春元,万志,张立国.双通道红外光谱辐射计的研制及标定[J].光学技术,2006,32(5):773-774. 被引量:3
  • 4戎志国,张玉香,贾凤敏,谭世祥,刘京晶,张艳,刘诚,张鹏.利用南海水面开展我国静止气象卫星红外通道在轨辐射定标[J].红外与毫米波学报,2007,26(2):97-101. 被引量:16
  • 5I.J.Barton,P.J.Minnett,K.A.Maillet et al..The Miami2001infrared radiometer calibration and intercomparison.part II:shipboard results[J].J.Atm.&Oceanic Technol.,2004,21(2):268-283.
  • 6R.Branch,A.T.Jessup,P.J.Minnett et al..Comparisons ofshipboard infrared sea surface skin temperature measurementsfrom the CIRIMS and the M-AERI[J].J.Atm.&OceanicTechnol.,2008,25(4):598-606.
  • 7P.J.Minnett,R.O.Knuteson,F.A.Best et al..The marine-atmospheric emitted radiance interferometer:a high-accuracy,sea-going infrared spectroradiometer[J].J.Atm.&OceanicTechnol.,2001,18(6):994-1013.
  • 8A.T.Jessup,R.A.Fogelberg,P.J.Minnett.Autonomousshipboard infrared radiometer system for in-situ validation ofsatellite SST[C].SPIE,2002,4814:222-229.
  • 9A.Jessup,R.Branch.Integrated ocean skin and bulktemperature measurements using the calibrated infrared in situmeasurement system(CIRIMS)and through-hull ports[J].J.Atmo.&Oceanic Technol.,2008,25(4):579-597.
  • 10C.Donlon,I.S.Robinson,M.Reynolds et al..An infrared seasurface temperature autonomous radiometer(ISAR)fordeployment aboard volunteer observing ships(VOS)[J].J.Atm.&Oceanic Technol.,2008,25(1):93-113.

引证文献3

二级引证文献19

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部