摘要 建立了锥板电极系统来模拟气体绝缘金属封闭输电线路(gas insulated transmission line,GIL)中同轴圆柱结构的电场分布,研究了直流下SF6中环氧树脂绝缘子的填料和形状对其闪络特性的影响,结果表明,直流GIL中填料为SiO2的环氧树脂绝缘子在短时加压和长期耐压试验中的绝缘性能都是最优良的。还介绍了基于锥板电极的直流GIL绝缘子外形结构优化的注意事项和绝缘子充电时间常数的近似求取方法。 Gas insulated transmission line (GIL) can be used to substitute part of overhead transmission line or power cable under special environments to enhance the flexibility of choosing wansmission corridor. The key factor impacting the insulation level of GIL is the charge accumulation along the surfaces of support insulators in DC environment. In this paper, a cone-plate electrode assembly is built to simulate the electric field distribution of coaxial cylindrical structure inside the GIL under DC voltage and the impacts of the filler and the shape of epoxy resin insulator under different SF6 pressures in DC environment on its flashover characteristic are researched. Test results show that in DC GIL the epoxy resin insulator using SiO2 as the filler is indicative of the best insulation performance in short-term voltage impressing and long-term voltage withstanding tests. The points, which attentions should be paid to, in the optimization of contour structure of cone-plate electrode assembly based epoxy resin insulator for DC GIL and the method to approximately acquire charging time constant of insulator are proposed.
出处 《电网技术》 EI CSCD 北大核心 2010年第8期155-159,共5页 Power System Technology
基金 国家自然科学基金项目(50877073)~~
关键词 环氧树脂绝缘子 直流闪络特性 表面电荷积聚 闪络电压 表面电导率 时间常数 epoxy resin insulator DC flashover characteristic surface charge accumulation flashover voltage surface conductivity time constant
  • 相关文献

参考文献19

  • 1范建斌,于永清,刘泽洪,赵杰,宿志一,刘永东,王茁.±800 kV特高压直流输电标准体系的建立[J].电网技术,2006,30(14):1-6. 被引量:64
  • 2Benato R, Carlini E M, Di M C, et al. Gas insulated transmission lines in railway galleries[J]. IEEE Transactions on Power Delivery, 2005, 20(2): 704-709.
  • 3Koch H J. Gas-insulated transmission line (GIL)[C]. Power Engineering Society General Meeting, Toronto, Canada, 2003.
  • 4TakinamiN, Kobayashi S, MiyazakiA. Applications oftheworld's longest gas insulated transmission line in Japan[C]. Proceedings of the 7th International Conference on Properties and Applications of Dielectric Materials, Nagoya, Japan, 2003.
  • 5Hillers T. Gas insulated transmission lines (GIL): ready for the real world[C]. Power Engineering Society Winter Meeting, Singapore, 2000.
  • 6周浩,余宇红.我国发展特高压输电中一些重要问题的讨论[J].电网技术,2005,29(12):1-9. 被引量:266
  • 7汪沨,邱毓昌.气体绝缘开关装置(GIS)的近期发展动向[J].电网技术,2003,27(2):54-57. 被引量:80
  • 8汤浩,吴广宁,范建斌,李鹏,李金忠,王宁华.直流气体绝缘输电线路的绝缘设计[J].电网技术,2008,32(6):65-70. 被引量:45
  • 9Sabot A. Insulation go-ordination procedure for 420 kV gas insulated lines (GIL)[C]. Eleventh International Symposium on High Voltage Engineering, London, UK, 1999.
  • 10Volpov E K. Dielectric strength coordination and generalized spacer design rules for HVAC/DC SF6 gas insulated systems[J]. IEEE Transactions on Dielectrics and Electrical Insulation, 2004, 11(6): 949-963.

二级参考文献111

共引文献579

同被引文献205

引证文献14

二级引证文献362

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部