期刊文献+

用泄漏电流概率密度分布预警污秽绝缘子串闪络 被引量:10

Method of Flashover Prediction of Polluted Insulator Strings Using the Probability Density Function of Leakage Current
原文传递
导出
摘要 有效预警绝缘子污闪是确保电网安全的重要措施之一,但目前对预警判据缺乏系统研究,为此以XP-160和LXY4-160为试品进行了试验并根据试验结果依次采用希尔伯特变换法、直方图非参数估计法和泄漏电流水平穿越行为(LCA)法分析了污秽绝缘子泄漏电流特征;提出了泄漏电流包络线的分布特征能表征泄漏电流总体发展规律;建立了污秽绝缘子闪络判断准则。研究表明:XP-160绝缘子泄漏电流幅值>135mA的统计时间>93ms(即τ135=93ms)、而LXY4-160绝缘子泄漏电流幅值>110mA的统计时间>105ms(即τ110=105ms)时可发生污闪。试验结果验证了污秽绝缘子闪络判断准则的正确性,因此,可以利用该方法进行绝缘子污闪预警。 The characters of leakage current XP-160 and LXY4-160 insulator strings are investigated by Hilbert transform,non-parametric density estimating through the histogram method and the level crossing activity based on the test results. It is put forward that the distributing characteristic of leakage current's envelop includes the development rule of leakage current. The flashover prediction criterion is found based on above analysis,such as,to XP-160,τ135 is 93 mS,indicating that the mean time duration for the leakage current envelop staying above 135 mA at which will sufficiently cause flashover is 93 mS; to LXY4-160,τ110 is 105 mS,indicating that the mean time duration for the leakage current envelop staying above 110 mA at which will sufficiently cause flashover is 105 mS. The predicting results accord with the test results,so it is feasible to predict flashover on polluted insulator strings by this method.
出处 《高电压技术》 EI CAS CSCD 北大核心 2010年第7期1675-1680,共6页 High Voltage Engineering
基金 国家重点基础研究发展计划(973计划)(2009CB724503)~~
关键词 泄漏电流 污秽 绝缘子 闪络 水平穿越行为 包络线 leakage current polluted insulator flashover level crossing activity envelop
  • 相关文献

参考文献11

二级参考文献108

共引文献237

同被引文献199

引证文献10

二级引证文献84

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部