摘要
通过动态实验,深入研究了OH-碱度对磁化水抑垢率的影响规律和抑垢机理.当碱度大于8mmol/L时,可以应用磁化水抑垢.
By dynamic test, the effects of OH - alkalinity on the rate of restraining scale formation of magnetized water, and its mechanism are farther studied and magnetized water can be used to restrain scale formation when alkalinity is more than 8 mmol/L.
出处
《哈尔滨师范大学自然科学学报》
CAS
1999年第1期70-72,共3页
Natural Science Journal of Harbin Normal University
关键词
碱度
抑垢率
磁化水
锅炉
循环冷却水
Alkalinity
The rate of restraining scale formation
Magnetized water