摘要 目的人工髓、膝关节置换术后出血量较大,尤其是膝关节置换术后平均引流量达600~800ml,常需输血治疗。而异体输血可引起许多不良反应和并发症,因此自体输血技术日益受到重视。本文介绍自体输血的初步经验。方法自1991年起,我院骨关节科共对433例施行人工髋、膝关节置换术的患者采用了自体输血技术,主要方法包括术前预存自体血和术后引流血回输技术。结果单纯依靠术前预存自体血输血组,术后约有69%(258/374)的患者无需异体输血而顺利渡过围手术期,其中93.4%(241/258)为单侧关节置换患者,6.6%(17/258)为双膝、双髋或单侧膝髋同时置换的患者;而在单纯术后引流血回输组和两种方法结合组,这一比例则分别为36%(5/14)和75.6%(34/45)。结论采用术前预存自体血加术后引流血回输的方法,可使多数施行人工髋、膝关节置换术的病例避免了异体输血及由此带来的潜在危险。 Objective Blood transfusion is often needed in knee and hip replacements. Autologousblood transfusion is now being widely used because of the complications and untoward reactions of allogenicblood trandusion. Methods Since 1991, 433 patients undergoing knee or hip arthroplasties in this centrehave received autologous blood transfusion. The patients can be divided into three groups: The first group hadpreoperative storage and transfusion of autologous blood during the operation. The second group had reinfusionof shed blood after arthroplasty, and third had both. Results In the group of preoperative storage and au-to-donation, 69% of the patients (258/374) passed perioperative period successfully without allogenic bloodtransfusion, including 93. 4% (241/258) unilateral and 6. 6% (17/258) bilateral or ipsilateral arthroplas-ties. While in the other two groups, the results were 36% (5/14) and 75.6% (34/45) respectively. Con-clusions Preoperative selfdonation together with reinfusion of autologous shed blood can avoid the danger ofallogenic blood transfusion in the majority of arthroplasty cases.
出处 《中华骨科杂志》 CAS CSCD 北大核心 1999年第2期116-118,共3页 Chinese Journal of Orthopaedics
关键词 人工关节转换术 膝关节 自体输血 Blood transfusion, autologous Joint prosthesis Knee joint
  • 相关文献

参考文献2

共引文献15

同被引文献177

引证文献35

二级引证文献145

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部