摘要
目的:评价结肠镜下高频电圈套器联合尼龙绳套扎和/或钛夹钳夹摘除大肠宽蒂、大息肉的疗效及安全性.方法:结肠镜下宽蒂息肉先予尼龙绳套扎其息肉根部,再予高频电圈套器凝切;大息肉(直径大于2.0cm者)先予钛夹2-3枚在息肉根部钳夹,然后再用高频电圈套器分块凝切.结果:结肠镜治疗大肠息肉788例、其中宽蒂、大息肉156例(宽蒂67例、大息肉89例),经予上述方法进行内镜下摘除,一次性切除息肉102枚(65.38%),分次切除54枚(34.62%),均获满意疗效,其中即刻出血2例(1.28%),立即给予内镜下血凝酶喷洒、电凝和/或钛夹,即时止血,无迟发出血.全部病例无1例穿孔.结论:经结肠镜高频电圈套器摘除消化系宽蒂、大息肉前给予尼龙绳套扎和/或钛夹钳夹息肉根部,明显减少了出血、穿孔等并发症,突破了以往内镜治疗息肉关于大小、宽蒂等禁区,避免了手术引起的创伤,安全可靠,值得推荐.
AIM:To assess the efficacy and safety of nylon endoloop ligature and/or clamping with titanium clips in combination with colonoscopy-assisted high-frequency electric snare in the treatment of colorectal polyps.METHODS:Patients with colorectal polyps with wide peduncle underwent a nylon endoloop snare first,followed by treatment by colonoscopy-assisted high-frequency electric snare.For patients with polyps larger than 2 cm,clamping with titanium clips in combination with electrocoagulation and electrocision was performed.RESULTS:A total of 788 cases of colorectal polyps,including 67 with wide peduncle and 89 larger than 2 cm,were treated by colonoscopy.Of these cases,102 (65.38%) were resected totally,54 (34.62%) were excised in stages.Two patients (1.28%) suffered from immediate bleeding and underwent hemocoagulase treatment,electric coagulation and (or) clamping with titanium clips.No perforation occurred.CONCLUSION:Nylon endoloop ligature and/or clamping with titanium clips in combination with colonoscopy-assisted high-frequency electric snare is effective and safe in the treatment of large colorectal polyps with wide peduncle
出处
《世界华人消化杂志》
CAS
北大核心
2010年第17期1838-1841,共4页
World Chinese Journal of Digestology
关键词
结肠镜
高频电
圈套器
套扎
大肠息肉
Colonoscopy
High-frequency electricity
Snare
Loop ligature
Colorectal polyp