摘要 目的:分析CR在临床儿科疾病影像诊断中的应用价值。方法:884幅CR摄片与660幅增感屏-胶片摄片相比较,从理论到实践说明CR在临床儿科疾病影像诊断中的应用价值。结果:884幅CR摄片优片率为84.00%、660幅增感屏一胶片摄片优片率为53.80%,CR优片率超过30.20%。结论:CR的影像质量明显高于增感屏-胶片系统cR可获取丰富的诊断信息,信息后处理扩大了诊断范围,并入互联网可实行影像信息资源共享,有较强的临床应用价值。 Objective:Analysis the value diagnosis of in clinical pediatric diseases CR of applied.Methods:Compared 884 flake CR and 660 flake intensifing screen-film explained CR advantage in diagnosis of clinical pediatric diseases for theory and practice.Results:884 CR finer flake been 84.00%,660 flake finer intensifing screen-film been 53.80%.CR finer probability go beyond 30.20%.Cnnclnsion:CR mass exceeded intensifing screen-film,CR have abundance diagnosis information and broadande information area and into network carry out information res communion.have stronged value in diagnosis diseases.
出处 《中国医药导刊》 2010年第7期1103-1104,共2页 Chinese Journal of Medicinal Guide
关键词 CR 增感屏-胶片系统 临床应用价值 CR Intensifing screen-film Clinical application value
  • 相关文献

参考文献5

二级参考文献15

  • 1缪国勇,顾强.CR系统在床边摄影中的应用价值[J].实用放射学杂志,2006,22(3):377-378. 被引量:24
  • 2王卫星,潘鄂武民,王瑞.数字化X线摄影技术在急腹症的应用[M].北京:中国医药出版社,2007,56.
  • 3[3]Chotas HG.Floyd CE.Ravin CE.Memory artifact related to selenium-based digital radiography systems[J].Radiology,1997,203:881~883.
  • 4[1]Sakuma H, Takeda K, Hirano T, et al. Plain chest radiograph with computed radiography: improved sensitivity for the detection of coronary artery calcification. AJR, 1988,151:27-30.
  • 5[2]Kogutt MS, Jones JP, Perkins DD. Low-dose digital computed radiography in pediatric chest imaging.AJR, 1988,151:775-779.
  • 6[3]Weatherburn GC, Bryan S, Davies JG. Comparison of doses for bedside examinations of the chest with conventional screen-film and computed radiography: results of a randomized controlled trial. Radiology, 2000, 217:707-712.
  • 7[4]Gupta AK. Role of imaging in pediatric respiratory diseases. Indian J Pediatr, 1999, 66:915-922.
  • 8[5]Hufton AP, Doyle SM, Carty HM. Digital radiography in paediatrics: radiation dose considerations and magnitude of possible dose reduction. Br J Radiol, 1998, 71:186-199.