期刊文献+

选择测定水样中硫酸盐浓度方法的比较研究 被引量:3

A Comparison Research of Choosing Method of Testing Concentration of Sulfate in Water Samples
在线阅读 下载PDF
导出
摘要 文章就斗门自来水公司需要选择测定水样中硫酸盐浓度的方法进行了比较研究,比较对象为铬酸钡分光光度法的冷热两种方法。通过比较研究表明,铬酸钡分光光度冷法操作较热法简单,并且在测定含低浓度的硫酸盐的水样时,精密度也比热法高。该项研究有助于斗门自来水公司做出选择铬酸钡分光光度冷法作为测试水样中硫酸盐浓度方法的决策。 To help Doumen Water Company to choose the assay of lcsting concentration of sulfate in watcr, a comparison research was held to compare cold one and thermal one of barium chromate spectrophotometry method. By comparing the results of the experiments, it showed that the cold method was relatively simpler than thermal one, and was more accurate when it was used in testing the water which had sulfate in low concentration. Since that, it was better for Doumen Water Company to use the cold method.
作者 黄凤珍
出处 《广东化工》 CAS 2010年第7期110-111,114,共3页 Guangdong Chemical Industry
关键词 硫酸盐 铬酸钡分光光度法 冷法 热法 sulfate barium chromate spectrophotometry cold method theirmal method