微波热致超声成像系统天线设计 被引量:1

Antenna design of microwave induced thermo-acoustic tomography system
在线阅读 下载PDF
导出
摘要 为了改善微波能量辐射的均匀程度,设计了一个矩圆过渡喇叭。在加入生物组织模型后进行仿真优化,并根据仿真优化结果制作了一个矩圆过渡喇叭。测试结果表明:此设计将系统的反射系数改善了9 dB以上。同时,对矩圆过渡喇叭和BJ-22矩形波导进行微波热致超声信号对比实验,比较分析结果表明:该设计可有效地改善微波能量辐射的均匀性,对设计更高效的微波脉冲馈源提供了重要参考。 In order to improve the uniformity of microwave energy radiation, the authors designed a rectangular-circular horn according to the simulation optimization results with introduction of biological tissue model. Experimental results show that this design reduces the reflection coefficient by over 9 dB. Meanwhile, we implemented an experiment about microwave heat-induced ultrasound between rectangular-circular horn and BJ-22 rectangular waveguide. By comparing the thermo-acoustic signals, it is demonstrated that this design improves the uniformity of microwave radiant energy. The work in this paper can provide important reference to design more effective microwave pulse feed.
出处 《电波科学学报》 EI CSCD 北大核心 2010年第3期543-547,共5页 Chinese Journal of Radio Science
基金 国家自然科学基金(NO.60927002 NO.60728101) 四川省杰出青年学科带头人培养计划(08ZQ026-39)
关键词 微波脉冲 波导 热声信号 热声成像 microwave pluses waveguide thermo-acoustic signals thermo-acoustic tomography
  • 相关文献

参考文献10

  • 1WANG L V, YANG X. Boundary conditions in photoacoustic tomography and image reconstruction [J]. Journal of Biomedical Optics, 2007, 12 (014027) : 1-10.
  • 2ZENG Xue zhi, WANG Gang. Numerical study of microwave-induced thermoacoustic effect for early breast cancer detection [C]//IEEE Antennas and Propagation Society International Symposium. Washington, USA.. IEEE, 2005.
  • 3聂在平,于万宝,陈国平,赵志钦,LIU Q.H..微波致热超声成像系统的研究[J].电子科技大学学报,2009,38(2):218-221. 被引量:3
  • 4陈腾博,刘琳琳,焦永昌,张福顺.一种双频段圆锥喇叭天线的设计[J].电波科学学报,2007,22(6):991-994. 被引量:4
  • 5KU Geng, WANG L V. Scanning microwave-induced thermoacoustic tomography: signal, resolution and contrast [J]. Med Phys, 2001, 28(1): 4-10.
  • 6谢处方,饶克谨.电磁场与电磁波[M].北京:高等教育出版社,2006.
  • 7杜彪,林金才,钟顺时.混合模介质加载圆锥喇叭的传播和辐射特性[J].电波科学学报,1995,10(1):39-46. 被引量:5
  • 8谢处方,邱文杰.天线原理与技术[M].成都:西北电讯工程学院,1985.
  • 9XU Y, WANG L H. Effects of Acoustic Heterogenei- ty in breast thermo acoustic tomography[J]. IEEE Trans on Ultrasonics, Ferroelectrics and Frequency Control, 2003, 50(9): 1134-1146.
  • 10何山红,傅永生.分析宽频带、双极化、恒束宽四脊喇叭的混合方法[J].电波科学学报,2002,17(2):160-165. 被引量:13

二级参考文献19

  • 1KONGLing-jiang.Research on Signal Processing Arithmetic of Subsurface Ground Penetrating Radar[J].Journal of Electronic Science and Technology of China,2005,3(2):189-190. 被引量:1
  • 2杜彪,林金才,钟顺时.混合模介质加载圆锥喇叭的传播和辐射特性[J].电波科学学报,1995,10(1):39-46. 被引量:5
  • 3NASONI R L, EVANOFF G A Jr, BOWEN T. Thermoacoustic emission by deeply penetrating microwave radiation[C]//1984 IEEE Ultrasonics Symposium Proceedings. Dallas, TX: IEEE, 1984.
  • 4WANG L V, YANG X. Boundary conditions in photoacoustic tomography and image reconstruction[J]. Journal of Biomedical Optics, 2007, 12(014027): 1-10.
  • 5KRUGER R A, STANTZ K. Thermoacoustic CT of the breast [C]//Proceeding of SPIE. San Diego, USA: [s.n.] 2002.
  • 6ZENG Xue-zhi, WANG Gang. Numerical study of microwave-induced thermoacoustic effect for early breast cancer detection [C]//IEEE Antennas and Propagation Society International Symposium. Washington, USA: IEEE, 2005.
  • 7DIEBOLD G J, SUN T, KHAN M I. Photoacoustic monopole radiation in one, two, and three dimensions[J]. Physical review letters, 1991, 64(24): 3384-3387.
  • 8DIEBOLD G J, SUN T. Properties of optoacoustic waves in one, two, and three dimensions [J]. Acoustica, 1994, 80: 339-351.
  • 9KU Geng, WANG L V. Scanning microwave-induced thermoacoustic tomography: signal, resolution and contrast [J]. Meal Phys, 2001, 28(1): 4-10.
  • 10XU Yuan, WANG L V. Signal processing in microwave- induced thermoacoustic tomography[C]//Proceeding of SPIE. San Jose CA: IEEE, 2001.

共引文献68

同被引文献4

引证文献1

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部