期刊文献+

1430例尿沉渣镜检和尿液分析仪检测结果分析 被引量:12

Results analysis of urine sediment detection with microscopy and urine analyzer detection in 1430 urine samples
暂未订购
导出
摘要 目的:探讨尿沉渣显微镜镜检法和尿液分析仪干化学法在尿液常规检测中的差异。方法:利用尿沉渣显微镜镜检法和尿分析仪干化学法对1 430例随机尿标本进行检测。结果:(1)尿沉渣镜检白细胞阳性(>3个/HP)73例,阴性1 357例,阳性率5%;而尿分析仪干化学法检测白细胞阳性(±~+++)141例,阴性1 289例,阳性率9.9%,尿分析仪干化学法检测阳性患者例数比尿沉渣镜检多68例,阳性率高出4.9%,统计学差异有显著性(P<0.01)。(2)尿沉渣镜检红细胞阳性(>3个/HP)98例,阴性1 332例,阳性率7.4%;而尿分析仪干化学法检测红细胞阳性(±~+++)77例,阴性1353例,阳性率5.7%,两者比较差异无显著性。结论:尿沉渣显微镜镜检法与尿分析仪干化学法在白细胞检测方面存在差异,尿分析仪干化学法结果阳性标本应加以镜检确定。 Objective:To investigate the difference between urine sediment detection with microscopy and dry chemical urine analyzer detection in urine routine test.Methods:1430 urine samples were randomly collected and detected by urine sediment detection with microscopy and dry chemical urine analyzer.Results:WBC positive(3 WBC/HP) by urine sediment microscopic detection was in 73 samples,negative in 1357 samples,with the positive rate of 5%;while WBC positive(±~+++) by dry chemical urine analyzer in 141 samples,negative in 1289 samples,with the positive rate of 9.9%,the number of WBC positive by urine analyzer was 68 more than tha tby urine sediment microscopic detection,the positive rate was higher by 4.9%,there was statistically significant difference(P〈0.01).RBC positive(3 RBC/HP) by urine sediment microscopic detection was in 98 samples,negative in 1332 samples,with the positive rate of 7.4%;while RBC positive(±~+++) by urine analyzer was 77 samples,negative 1353 samples,with the positive rate of 5.7%,there was no statistical difference between the two methods.Conclusion:Urine sediment detection with microscopy and dry chemical urine analyzer have difference in detection of urine routine test,the positive results by urine analyzer should be determined by microscopy.
作者 朱华
出处 《现代医药卫生》 2010年第14期2112-2113,共2页 Journal of Modern Medicine & Health
关键词 尿沉渣镜检 尿液分析仪 细胞 Urine sediment detection with microscopy Urine analyzer Cell
  • 相关文献

参考文献2

共引文献251

同被引文献55

  • 1孙静,杨利黎.尿液综合分析在临床中的应用[J].检验医学与临床,2005,2(2):54-55. 被引量:7
  • 2吴华军,王宇军,陈灵芝.UF-1000尿沉渣流式细胞仪在尿红细胞分析中的应用[J].浙江医学,2009(12). 被引量:5
  • 3徐银萍,王胜奎.尿液分析仪与尿沉渣镜检两种方法的比较分析[J].现代检验医学杂志,2006,21(3):71-72. 被引量:28
  • 4胡娇丽.尿液干化学分析法与尿沉渣镜检两种方法的比较[J].中外健康文摘,2012,9(17):204-205.
  • 5Saleh A, Stephanson NN, Granelli I, et al. Evaluation of a direct high-capacity target screening approach for urine drug testing us- ing liquid chromatography-time-of-flight mass spectrometry[J]. J Chromatogr B Analyt Technol Biomed Life Sci,2012,909:6-13.
  • 6Melanson SE. The utility of immunoassays for urine drug testing[J]. Clin Lab Med, 2012,32 (3) : 429-447.
  • 7Goswami RP, Goswami RP, Das S, et al. Testing urine samples with rK39 strip as the simplest non-invasive field diagnosis for visceral leishmaniasis:an early report from eastern India[J]. Po- stgrad Med,2012,58(3) :180-184.
  • 8Chaturvedi AK, Sershon JL, Craft K J, et al. Effects of fluid load on human urine characteristics related to workplace drug testing[J]. J Anal Toxicol,2013,37( 1 ) :5-10.
  • 9Poklis JL, Wolf CE, Goldstein A, et al. Detection and quantifica- tion of tricyclic antidepressants and other psychoactive drugs in urine by HPLC/MS/MS for pain management compliance testing[J]. J Clin Lab Anal,2012,26(4) :286-294.
  • 10Robinson JP, Burrell SA, Avi-Itzhak T, et al. Validity testing of the stopwatch urine stream interruption test in radical prostatec- tomy patients[J]. J Wound Ostomy Continence Nurs,2012,39 (5) :545-551.

引证文献12

二级引证文献35

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部