期刊文献+

HIV抗体纳米免疫磁珠快速检测试剂的研制 被引量:1

Development of a rapid test kit for antibody to HIV by nano immunomagnetic lateral flow method
原文传递
导出
摘要 目的 研制一种用纳米免疫磁珠层析技术用以检测HIV抗体的快速诊断试剂.方法 运用碳二亚(EDC)将重组的HIV抗原gp41、gp36偶联到200 nm的超顺磁纳米颗粒上,在硝酸纤维素(NC)膜上包被gp41、gp36抗原,制备成免疫层析检测卡,然后对检测卡进行性能分析评估.结果 对HIV抗体国家参考品血清盘(胶体金类)检测,符合要求;对20份HIV抗体阳性和600份抗体阴性临床血清检测,灵敏度为100%,特异性为98.5%.检测卡室温保存12个月性能稳定.结论 研制出一种纳米免疫磁珠HIV抗体检测试剂,具有检测简便、快速、稳定性好和适于现场检测等特点. Objective To develop a rapid test kit for antibody to HIV by nano immunomagnetic lateral flow method.Methods A rapid test kit was developed by conjugation of the HIV antigen gp41 and gp36 to 200nm super paramagnetic particles by carbodiimide (EDC) and coating of the HIV antigen sp41 and gp36 to nitrocellulose membrane.Then the kit was evaluated with serials of experiments.Results The kit was qualified with examination of national reference panel of anti-HIV antibody for colloidal gold diagnostic kit.The sensitivity was 100% by tested with 20 HIV antibody positive sera,the specificity was 98.5% by tested with 600 HIV antibody negative sera,respectively.The stabilitv of the kit was over 12 month by storage at room temperature.Conclusion A diagnostic kit for antibody to HIV was developed with the advantages of convenience,rapid test,good stability and point of care.
出处 《中华实验和临床病毒学杂志》 CAS CSCD 北大核心 2010年第3期235-237,共3页 Chinese Journal of Experimental and Clinical Virology
基金 天津市科技支撑计划重点项目(08ZCKFSH00400)
关键词 HIV抗体 纳米免疫磁珠 免疫层析 快速检测 HIV antibodies Nano immunomagnetic particle Lateral flow Rapid test
  • 相关文献

参考文献5

二级参考文献28

  • 1王福勇,刘克义,程义亮,黄炳成,于振华.斑点免疫金染色法检测恶性疟原虫循环抗原[J].中华医学检验杂志,1994,17(1):43-44. 被引量:4
  • 2刘煜凯,陈伟明,马以秀,冯仁丰.免疫层析法作早孕快速诊断测定[J].中华医学检验杂志,1995,18(6):364-367. 被引量:22
  • 3许文燕,邱茂锋,佐合拉.吐尔地,邢文革,蒋岩.第四代HIV抗原抗体酶联检测试剂缩短HIV检测窗口期的研究[J].中华检验医学杂志,2007,30(3):284-287. 被引量:63
  • 4[1]Davenport JM,Schlain B.Testing claimed minimal detectable concentrations of in vitro medical diagnostic devices[J].Clin Chem,2000,46:1669-1680.
  • 5[2]Diamandis EP,Yu J,Melegos DN.Ultrasensitive Prostate-specific antigen assaya and their clinical application[J].Clin Chem,l996,42:853-857.
  • 6[3]Stamey TA.Lower lin\mits of detection,Biological detection limits,functional sensitivity,or residual cancer detection? Sensitivity report on Prostate-specific antigen assays mislead clinicians[J].Clin Chem,1996,42:849-852.
  • 7Valkirs GE and Barton R. Immuno concentrationa new format for solid-phace immunoassays. Clin Chem, 1985;31 : 1427- 1431.
  • 8Spielberg F, Kabeya CM, Ryder RW,et al. Field testing and comparative evaluation of rapid visually read screening assays for antibody to human immuneodeficiency virus. Lancet, 1989,1 : 580 - 584.
  • 9Huang Q, Lan X,Tong T, et al. Dotimmuneogold filtration assay as a screening test for syphilis. J Clin Microbiol, 1996,34(8):2011 -2013.
  • 10Genaro O,Melo MA,Costa RT da, et al. Evaluation of the Immunochromatography assay for the diagnosis of canine visceral leishmaniasis.A prospective study on experimentally infected dogs with leishmania chagasi. Memorias do Instituto Oswaldo Cruz, 1996,91:192- 193.