期刊文献+

基于温湿度独立控制的水蓄冷空调系统 被引量:14

Chilled water storage air conditioning system with independent temperature-humidity control
在线阅读 下载PDF
导出
摘要 阐述了基于温湿度独立控制的水蓄冷空调系统(CWS-ITHC)的工作原理、特点和设计方法。案例分析结果表明,该系统除具备温湿度独立控制系统的优点外,还具有减小设备容量、节省系统初投资,蓄冷密度(温差)大、大幅度减小蓄冷槽体积,利用夜间低价电力蓄冷、大幅减少运行费用等特点。 Explains the working principle and characteristics of the chilled water storage air conditioning system with independent temperature-humidity control(CWS-ITHC)and its design method.A case study shows that besides the basic advantages of the independent temperature-humidity control system,the system is featured reduced necessary chiller capacity to economize the initial investment,significantly decreased reservoir volume for its high cold storage density,and significantly lowered operational expenses by producing and storing the cold thermal energy with discounted power price during nighttime.
出处 《暖通空调》 北大核心 2010年第6期36-41,共6页 Heating Ventilating & Air Conditioning
关键词 温湿度独立控制 水蓄冷 独立新风系统 设计方法 independent temperature-humidity control chilled water storage dedicated outdoor air system design method