康普顿散射对X射线透射谱的影响 被引量:1

Compton effect on X-ray transmission spectrum
在线阅读 下载PDF
导出
摘要 采用一定组分的材料对X射线进行辐射屏蔽,可以吸收大部分的低能光子,减少X射线对电子系统的辐射损伤。但通过研究发现,由于康普顿散射的影响,在一定条件下,透射谱中的低能光子数不但没有减少反而大于入射谱,这对于电子元器件的辐射防护是不利的。通过改变入射源光子能谱、探测器位置、屏蔽材料类型以及屏蔽材料厚度等参量,采用蒙特卡罗方法计算并分析了散射光子对X射线透射谱的影响,得到了康普顿散射光子对X射线透射谱的影响规律,并提出了降低散射光子影响的几种措施。 Shield material with some certain composition can absorb a large part of low energy photon of X-ray and reduce the radiation effect on electronic component.However,in some cases,photon quantity of several low energy bins in transmission spectrum will be larger than that in incidence spectrum due to Compton scattered photons.This is disadvantageous for radiation protection.The study discussed such factors relative to scattered photon impact as source photon energy,the place of detector,the composition and the thickness of shield material.Under several different conditions,X-ray transmission spectra were calculated.The rule of Compton photons affecting on X-ray transmission spectrum was found.Lastly,some countermeasures were put forward.
出处 《信息与电子工程》 2010年第3期328-330,340,共4页 information and electronic engineering
关键词 X射线 康普顿效应 散射光子 蒙特卡罗法 辐射屏蔽 X-ray Compton effect scattered photon Monte Carlo radiation shield
  • 相关文献

参考文献7

二级参考文献47

  • 1赵国英,陈睿,张俊,林宗楷,李华.数字人与人体仿真[J].计算机仿真,2003,20(z1):520-524. 被引量:7
  • 2张晓斌,魏永祥,韩德民.数字化虚拟人体与鼻外科[J].国外医学(耳鼻咽喉科学分册),2005,29(1):44-48. 被引量:7
  • 3王丰春,杨忠勤,田新珊.用蒙特卡罗方法计算光子外照射对人体产生的有效剂量[J].核动力工程,2006,27(1):47-50. 被引量:4
  • 4刘芳,陈英茂,白净.基于医学图像处理的放射性药物内照射剂量计算[J].北京生物医学工程,2007,26(2):120-123. 被引量:2
  • 5Tables of X-Ray Mass Attenuation Coefficients and Mass Energy-Absorption Coefficients,Ionizing Radiation Division,Physics Laboratory National Institute of Standards and Technology,1996,4.
  • 6MCNP4C Transport code System,CCC-700,Los Alamos National Laboratory.
  • 7D.W.O.Rogers,I.Kawrakow,J.P.Seuntjens,B.R.B.Wakers andE.Mainegra-Hing,NRC User Codes for EGSnrc[R].NRCC Report PIRS-702 (revB),Ionizing Radiation Standards National Research Council of Canada Ottawa,March 2005.
  • 8J.Borg,I.Kawrakow,D.W.O.Rogers,J.P.Seuntjens.Experimental verification of EGSnrc Monte Carlo calculated ion chamber response in low energy photo beams[C].proceedings of the 22 Annual EMBS International Conference,July 23-28,2000.
  • 9Sung-Joon Ye,Ivan A Brezovich,Prem Pareek and Shahid A N aqvi.Benchmark of PENELOPE code for low-energy photo transport:dose comparisons with MCNP4 and EGS4[J].Phys.Med.Biol,2004,49.387-397.
  • 10Timothy D.Solberg,John J.DeMarco,Indrin J.Chetty,etc.A review of radiation dosimetry applications using the MCNP Monte Carlo code[R].Los Alamos National Laboratory report(2001).

共引文献9

同被引文献34

引证文献1

二级引证文献9

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部