摘要
以实际产品的复杂载流,散热系统在SF_6,空气中实测的稳定温升与气压高低,电流大小的关系为依据,提出对任何封闭式SF_6开关电器有参考价值的稳态温升的计算方法,这是从理论上决定其温升的有效手段。
On the ground of experiment results for the steady state of temperature rise in a actual circuit breaker a method of temperature rise calculation with can give a reference to any enclosed switchgear has been proposed in this paper.
出处
《高压电器》
CAS
CSCD
北大核心
1989年第6期35-38,共4页
High Voltage Apparatus
关键词
SF6断路器
稳态温升
temperature rise, SF6 circuit breaker, computation