摘要
文中阐述了湿度分析仪在催化重整装置的应用。分析了由德国恩德豪斯(E+H)公司生产的WMY770+DY73Z型湿度分析测量系统的特点及组成、工作原理。说明了在样品预处理过程中采取的措施及保证仪表测量的准确性标定操作的正确方法。
This paper expounded the application of humidity analyzer in catalytic reformer.It analyzed the characteristic,composition,operating principle of the WMY770+DY73Z humidity analyzing and measuring system produced by E+H Company of Germany.It explained measures taken during sample pretreatment and proper method for ensuring accuracy calibration operation of instrument measurement.
出处
《炼油与化工》
2010年第3期39-42,共4页
Refining And Chemical Industry
关键词
湿度
标定
测量
Humidity
calibration