Segmented HPGe平面型位置灵敏探测器阵列的γ成像分析

Gamma-ray imaging analysis by using array of segmented planar HPGe detectors
原文传递
导出
摘要 探测器位置分辨能力的高低是实现γ成像的一个重要指标.Segmented HPGe平面型位置灵敏探测器能够很好地给出γ射线与探测器晶体相互作用的作用点位置信息.利用由这种探测器组成的探测器阵列对^(22)Na标准源进行了γ成像实验.结果能够区分出标准源两个不同的摆放位置的细微差别,并与实际情况符合得很好.从而检验了Segmented HPGe平面型位置灵敏探测器的位置分辨能力. Detector having high position sensitivity is a key factor to carry out γ-ray imaging successfully. Segmented planar HPGe detector with good position sensitivity can determine the location of the γ-ray interaction point in the detector. The γ-ray imaging experiment with the detector array of this type has been done by using a 22Na standard source. The two locations of the standard source with very small difference was reproduced quite well and the position-resolving power of the segmented planar HPGe detector was verified from the results.
出处 《中国科学:物理学、力学、天文学》 CSCD 北大核心 2010年第6期748-752,共5页 Scientia Sinica Physica,Mechanica & Astronomica
基金 国家自然科学基金资助项目(批准号:10805058)
关键词 SEGMENTED HPGE 探测器阵列 位置分辨能力 γ成像 标准源 Segmented HPGe, detector array, position resovling power,γ imaging, standard source
  • 相关文献

参考文献5

  • 1Tempany C M C, McNeil B J. Advances in biomedical imaging. J Am Med Assoc, 2001, 285:562-567.
  • 2Bignami G F. Gamma-ray astronomy with INTEGRAL. Science, 2002, 298:1560-1561.
  • 3Shimoura S. Position sensitivity of Ge detectors and its applications to in-beam nuclear spectroscopy. Nucl Instrum Methods A, 2004, 525: 188-192.
  • 4Kroll Th, Bazzacco D. Simulation and analysis of pulse shapes from highly segmented HPGe detectors for the γ-ray tracking array MARS. Nucl Instrum Methods A, 2001, 463:227-249.
  • 5Kurokawa M, Shimoura S, Iwasaki H, et al. Pulse shape simulation and analysis of segmented Ge detectors for position extraction. IEEE Trans Nucl Sci, 2003, 50:1309-1316.