摘要
催化装置的吸收稳定系统的液位计引出管在运行中出现开裂现象,通过电镜观察、能谱分析、X射线衍射分析,以及金相检测等手段,对开裂的原因及机理进行了分析,并提出了关于材料本身和工艺的改进措施。
The level gauge nozzle of adsorption tower often appeared crack during operation,crack reason and mechanism were analyzed by SEM,EDX,XRD and metallographical test,the improvement measures were put forward finally.
出处
《辽宁化工》
CAS
2010年第5期551-553,共3页
Liaoning Chemical Industry
关键词
催化裂化
吸收系统
腐蚀失效
Catalytic cracking
Adsorption system
Corrosion failure analysis