期刊文献+

高分辨率纸介质打印与干式胶片打印的临床对比研究 被引量:5

High Resolution Laser Paper Prints and Dry Laser Film Copies in Radiology:A Comparative Study
原文传递
导出
摘要 目的探讨医用高分辨率纸介质激光打印机的临床应用价值。资料与方法分别采用BELSON纸介质、AGFA干式激光打印机打印CT、DR及MR图像(阳性组91例、阴性组118例)。由三名放射诊断医师分别进行双盲法阅片。通过诊断结果分级及满意度评分评价此两种硬拷贝的诊断效能。阅片结果采用SPSS软件进行卡方检验和受试者操作特征曲线(ROC)分析。结果纸介质打印与胶片打印的ROC曲线下面积无显著性差异(Z=0.97,P>0.05);综合评分中,前者明显优于后者(χ2=14.4,P<0.05),尤其是能够更直观地展现三维重建影像。结论高分辨率纸介质激光打印机能够提供高品质的硬拷贝图像,且不影响诊断效能;具有经济、环保、直观、高效的独特优势。 Objective To explore the clinical value of high resolution paper printer in output of digital images. Materials and Methods The CT,DR and MR images were divided into positive group (91 cases) and negative group (118 cases). The images were printed respectively by a dry laser printer (AGFA) and a laser paper printer (Belson). Three senior radiologists read the images using double-blinded method. Diagnostic efficacy was evaluated through the diagnostic results and satisfaction scores. Receiver operating characteristic (ROC) curve was painted by SPSS. Results As to area under ROC,there was no significant difference between the two hardcopies (z=0.97,P0.05). Paper printer was superior to dry laser printer in satisfaction scores (χ2=14.4,P0.05),particularly for the reconstructive images. Conclu-sion Without the decline of diagnostic efficacy,paper printer provides high quality,environment-friendly,high-speed,direct-viewing,and cost-effective advantages.
出处 《临床放射学杂志》 CSCD 北大核心 2010年第5期680-682,共3页 Journal of Clinical Radiology
关键词 纸介质激光打印机 干式胶片相机 受试者操作特征曲 医学数字成像与通讯 图像存档与传输系统 Paper laser printer Dry laser printer Receiver operating characteristic Digital imaging and communication in medicine Picture archiving and communication system
  • 相关文献

参考文献5

  • 1刘虹,Cathy Lau.DICOM纸质医疗影像输出方案的应用前景及效益分析[J].医学综述,2007,13(2):150-153. 被引量:14
  • 2Bley TA, Kotter E, Saueressig U, et al. Using Receiver Operating Characteristic Methodology to Evaluate the Diagnostie Quality of Radiography on Paper Prints Versus Film. AJR,2003,181:1487.
  • 3SchueIler G, Kaiudl E, Matzek WK, et al. Image Quality of a Wet Laser Printer Versus a Paper Printer for Full-Field Digital Mammograms. AIR,2006,186 : 38.
  • 4Schulze RK, Schulze D, Voss K, et al. Quality of individually calibrated customary printers for assessment of typical dental diagnoses on glossy paper prints: a muhicenter pilot study. Oral Surg Oral Med Oral Pathol Oral Radiol Endod ,2008,106:578.
  • 5Ibbott GS, Zhang Y, Mohiuddin M, et al. Reproduction of radiologic images on plain paper. RadioGraphics, 1998,18:755.

二级参考文献6

  • 1ACR-NEMA. Digital Imaging and Communications in Medicine (DICOM) [ S]. Part 1 : Introduction and Overview PS3.1-2004 Page 5.
  • 2Horiil Steven C, Prior Fred W, Bidgood W, Dean, et al. DICOM : An introduction to the Standard.http://www.csd.uoc.gr.
  • 3林怡君 陈瑞甫 韩怀恩 等.由医院资讯系统及放射医学数位化之演进探讨IHE之未来发展[J].医疗资讯杂志,2004,13(1):123-143.
  • 4宿志弘,陆树立,邢华.杭州市医疗废物、感光材料废物、汽车维修行业废物产生和处置现状及应对措施调研报告[R].杭州市科技情报调研计划,计划编号200320.
  • 5高培毅.迈向“以病人为中心”的重要一步——重新认识影像存档与通讯系统[J].中华放射学杂志,1999,33(12):797-798. 被引量:25
  • 6陈浩,李本富.医学图像处理技术新进展[J].第四军医大学学报,2004,25(5):478-479. 被引量:17

共引文献13

同被引文献49

  • 1李昌领,张虹.DICOM医学图像胶片输出技术的实现[J].计算机工程与设计,2005,26(8):2226-2228. 被引量:4
  • 2郭力.激光相机的工作原理[J].医疗卫生装备,2006,27(2):71-71. 被引量:24
  • 3刘虹,Cathy Lau.DICOM纸质医疗影像输出方案的应用前景及效益分析[J].医学综述,2007,13(2):150-153. 被引量:14
  • 4王恒桓.医用激光相机原理结构及维护[J].医疗卫生装备,2007,28(2):68-69. 被引量:5
  • 5郭京海,陈艳冬.医学影像纸介质打印系统的分析与研究[J].医疗卫生装备,2010,31(4):338-339.
  • 6Bley TA,Kotter E,Sauemssig U,et al.Using receiver operanng characterisfc methodology to evaluate the diagnostic quality of radiography on paper prinl versus flm.AJR,2003,181(6):1487-1490.
  • 7Schueller G,Kaindl E,MatzekWK,et al.lmage quality of a wetLaser printer versus a paper printer for full2Field digital mammograms[J].AJR,2006,186(l):38-43.
  • 8Schulze RK, Schulze D,Voss K,et al.Quality of individually calibrated customary printers for assessment of typical dental diagnoses on glossy paper prints a multicenter pilot study[J].Oral Surg Oral Med Oral Pathol Oval Radiol Endod,2008,106(14):578-586.
  • 9Gerd Schueller,Elisabeth Kaindll,Wolfgang K Matzek,et al.lmage quality of a wet laser printer versus a paper printer for full-field digital mammograms [J].AJtL,2006,186(1):38-43.
  • 10Marfnoli C,Pretolesi F,Del-Bono V,et al.Benign lymphoepithelial lesion in HIV-positive patients; spectrum of findings at gray-scale and Doppler sonoaphy[J].AJR,1995,(165):532-534.

引证文献5

二级引证文献13

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部