期刊文献+

Study and practice of the controlling technique on heat-harm during the tunneling in Zhaolou mine

Study and practice of the controlling technique on heat-harm during the tunneling in Zhaolou mine
在线阅读 下载PDF
导出
摘要 This paper proposes the cooling system type and cooling equipment type which are deep mine with high temperature during the construction,and presents auxiliary cooling measures making up duct temperature rise since compression and heat transfer temperature rise. The cooling system designed against Zhaolou mine's ground temperature and weather conditions,with its sprinkler room handling an average temperature difference up to 19.5~23.8 ℃,and the average enthalpy difference could reach 48.4~60.7 kJ/kg. At the same time,it gets a series of basic data used for mine construction during the cooling system design and equipment selection according to the measured results; using the analysis software Matlab,it obtains the change relations between the temperature of sprinkler room and fan export supply air temperature,wind casing temperature rise and fan export supply air temperature,working face temperature and supply air temperature,used for the mine cooling which has the similar conditions.
出处 《Engineering Sciences》 EI 2008年第4期31-35,共5页 中国工程科学(英文版)
关键词 deep mine with high temperature mine development tunneling coaling 煤矿掘进 控制技术 冷却系统设计 热害 温度上升 MATLAB export 设备类型