摘要
采用火焰原子吸收光谱法测定粉煤灰中氧化镁的含量。用氢氟酸-高氯酸混合酸分解样品,以氯化锶消除其他元素的干扰。本方法操作简便、再现性好、灵敏度高,氧化镁浓度在0.10—2.00μg/mL之间线性关系良好,检出限可达0.02%,适用于粉煤灰中氧化镁的测定。
Magnesium oxide (MgO) in fly ash was determined by flame atomic absorption spectrometry(FAAS).The sample was dissolved in a mixed acid composed of HF and HClO4,and other elements could be eliminated by SrCl2.This method is characterized with easily operation,good reproductivity and high sensitivity.Also it represents a good linear relationship with MgO of 0.10—2.00μg/mL.The detection limit is 0.02%.This method can be used to the determination of MgO in fly ash.
出处
《光谱实验室》
CAS
CSCD
北大核心
2010年第3期1047-1049,共3页
Chinese Journal of Spectroscopy Laboratory
基金