期刊文献+

锅炉烟尘现场监测若干问题探讨 被引量:2

Discussion of Problems on Boiler Flue Dust On-spot Monitoring
在线阅读 下载PDF
导出
摘要 以动压平衡自动跟踪微电脑烟尘采样仪为例,从采样截面与测点布设、采样嘴的选择、采气体积、仪器显示异常情况原因分析、采样期间操作五个方面讨论锅炉烟尘现场监测中常见问题的解决办法。着重探讨了采气体积与烟尘浓度相对误差的关系。在允许烟尘浓度相对误差≤10%时,采集3个样品的条件下,当烟尘浓度C≥100mg/L,则按GB5468—91《锅炉烟尘测试方法》每个样品最小采气体积为334L;当烟尘浓度C≤100mg/L,则必须增加最小采气体积,才能满足烟尘浓度相对误差≤10%的要求。 For example a Dynamic pressure balance automatic tracking microcomputer dust sampling instrument,Discuss on-spot monitoring solutions to common problems from sampling section .measuring point laid.the choice of sampling mouth.gas sample volume.instrument displays abnormalities cause analysis and the sampling operation five aspects. Focuses on the relationship between the volume of gas and the relative error of dust concentration. Allowing the relative error of dust concentration ≤ 10% ,under the conditions of three samples collected,if the dust concentration C≥ 100mg/L,according to GB 5468-91 《boiler soot test method》,the minimum volume of each sample of gas is 334L (Standard state dry flue gas, Hereinafter) ;if the dust concentration C ≤ 100 mg/L,must increase the minimum volume of gas sample in order to meet the requirement of the dust concentration relative error≤ 10%.
作者 董海
出处 《科技信息》 2010年第11期385-385,共1页 Science & Technology Information
关键词 锅炉 烟尘 现场监测 Boiler Dust On-spot monitoring