期刊文献+

用于挥发性有机气体测定的化学阻抗传感器 被引量:2

A chemiresistor sensor for the determination of volatile organic compounds
在线阅读 下载PDF
导出
摘要 该文以碳粉掺杂的聚合物为敏感膜,以叉指电极为基底制作了测定挥发性有机气体的化学阻抗传感器。当敏感膜吸附有机气体时,敏感膜膨胀,导致膜中导电性的碳粉粒子距离增加,电阻也增加。同时,有机气体的吸附还引起敏感膜的介电常数改变,从而导致电阻、电容改变。通过传感器电阻电容的变化可以实现有机气体的定量测定。考察了敏感膜厚度、敏感膜中碳粉含量、及测定频率对传感器电阻电容响应的影响。该文还探讨了电阻和电容响应的机理。 A chemiresistor sensor was fabricated for the analysis of volatile organic compounds(VOCs) with carbon black(CB)-polymer composite as sensing film and interdigital electrodes.The film swelling upon absorbing VOCs results in an increase in the space among CB particles,and consequently an increase in resistance.Meanwhile the absorption of VOCs results in changes in the dielectric properties of the film,and consequently changes in the resistance and capacitance.The effects of polymer film thickness,CB content,and tested frequency on the resistance and capacitance in response to VOCs were investigated.The response mechanism was also discussed.
出处 《化学传感器》 CAS 2010年第1期54-59,共6页 Chemical Sensors
关键词 碳黑 聚合物 化学阻抗 传感器 Carbon black Polymer composite Capacitance and resistance response Chemiresistor
  • 相关文献

参考文献22

  • 1Fei Wang,Hongwei Gu,Timothy M Swager,et al.Carbon Nanotube/Polythiophene Chemiresistive Sensors for Chemical Warfare Agents[J].J.Am.Cbem.Soc,2008,130:5 392-5 393.
  • 2Severin Efick J,Lewis Nathan S.Relationships among Resonant Frequency Changes on a Coated Quartz Crystal Microbalance,Thickness Changes,and Resistance Response of Polymer-Carbon Black Composite Chemiresistors[J].Anal.Chem,2000,72:2 008-2 015.
  • 3Briglin Shawn M,Lewis Nathan S.Characterization of the Temporal Response Profde of Carbon Black-Polymer Composite Detectors to Volatile Organic Vapors[J].J.Phys.Chem,B,2003,107:11 031-11 042.
  • 4Vaid Thomas P,Burl Michael C,Lewis Nathan S.Comparison of the Performance of Different Discriminant Algorithms in Analyte Discrimination Tasks Using an Array of Carbon Black-Polymer Composite Vapor Detectors[J].Anal.Chem,2001,73:321-331.
  • 5Koscho Michael E,Grubbss,Robert H.Lewis Nathan S.Properties of Vapor Detector Arrays Formed through Plasticization of Carbon Black-Organic Polymer composites[J].Anal.Chem,2002,74:1 307-1 315.
  • 6Severin Erik J,Doleman Brett J,Lewis Nathan S.An Investigation of the Concentration Dependence and Response to Analyte Mixtures of Carbon Black/Insulating Organic Polymer Composite Vapor Detectors[J].Anal.Chem,2000,72:658-668.
  • 7Luo Cheng,Chakraborty Anirban.Effects of dimensions on the sensitivity of a conducting polymer Micmwire sensor[J].Microelectron J,2009,40:912-920.
  • 8Doleman Brett J,Sanner Robert D,Severin Erik J,et al.Use of Compatible Polymer Blends To Fabricate Arrays of Carbon Black-Polymer Composite Vapor Detectors[J].Anal.Chem.,1998,70:2 560-2 564.
  • 9Hopkins Alan R,Lewis Nathan S.Detection and Classification Characteristics of Arrays of Carbon Black/Organic Polymer Composite Chemiresistive Vapor Detectors for the Nerve Agent Simulants Dimethylmethylphosphonate and Diisopropylmethylphosponate[J].Anal.Chem.,2001,73:884-892.
  • 10Tillman Eric S,Koscho Michael E,Grubbs Robert H,et al.Enhanced Sensitivity to and Classification of Volatile Carboxylic Acids Using Arrays of Linear Poly (ethylenimine)-Carbon Black Composite Vapor Detectors[J].Anal.Chem.,2003,75:1 748-1 753.