摘要 目的探讨多层螺旋CT血管成像在血液透析患者自体动静脉内瘘功能不全中的临床价值。方法采用16层螺旋CT对14例自体动静脉内瘘功能不全的患者进行血管成像检查。对扫描的图像进行后处理,分别采用曲面重建(CPR)、最大密度投影(MIP)和容积成像(VR)进行三维重建。观察自体动静脉内瘘血管的显示情况。结果14例患者中,单纯吻合口狭窄1例;流入动脉狭窄3例,其中多处狭窄2例;流出静脉狭窄6例,其中多处狭窄3例,伴有明显的静脉侧支循环1例;流入动脉及流出静脉同时狭窄1例;流入动脉、流出静脉及吻合均狭窄1例;仅有动脉粥样斑块但无明显狭窄2例。并依据此结果,对12例患者进行了动静脉内瘘手术,其中8例在原内瘘同侧近心端手术,均获满意效果。结论多层螺旋CT血管成像检查相对无创、空间分辨率高,可以多角度、多方位、立体地显示内瘘血管病变,为自体内瘘功能不全的患者提供了1种有效的检查方法。
出处 《中国临床医生杂志》 2010年第5期39-41,共3页 Chinese Journal For Clinicians
  • 相关文献

参考文献6

  • 1于青,张郁苒,池琦,郁佩青,袁伟杰.维持性血液透析患者动静脉内瘘血管瘤样扩张的原因探讨及预防[J].中国血液净化,2009,8(6):301-304. 被引量:47
  • 2Doelman C,Duijm LE,Liem YS,et al.Stenosis detection in failing hemodialysis access fistulas and grafts:Comparison of color Doppler ultrasonography,contrast-enhanced magnetic resonance angiography,and digital subtraction angiography[J].J Vasc Surg,2005,42:739-746.
  • 3Edward G.Neyman,MD,Pamela T,et al.Hemodialysis Fistula Occlusion Demonstration With 64-Slice CT Angiography[J].J Comput Assist Tomogr,2006,30:157-159.
  • 4Cavagna E,D'Andrea P,Schiavon F,et al.Failing hemodialysis arteriovenous fistula and percutaneous treatment:imaging with CT,MRI and digital subtraction angiography[J].Cardiovasc Intervent Radiol,2000,23:262-265.
  • 5E.Karadeli,N.C.Tarhan,E.M.Kayahan,et al.Evaluation of failing hemodialysis fistulas with multidetector CT angiography:Comparison of different 3D planes[J].European Journal of Radiology,2009,69:184-192.
  • 6叶道斌,蔡祖龙,高建华.64层CT血管成像技术在颅内脑血管病变诊断中的应用[J].中国医刊,2007,42(5):34-36. 被引量:9

二级参考文献10

共引文献53

同被引文献52

  • 1鄢艳,孙庭,陈钦开,胡峰.动静脉内瘘术用于血液透析的临床分析[J].中国血液净化,2004,3(12):675-676. 被引量:12
  • 2李惠民,于红,刘士远,叶朝阳,戎殳,孙琳琳.血液透析之自体动静脉内瘘的CT血管造影初步研究[J].中国医学计算机成像杂志,2005,11(6):408-411. 被引量:7
  • 3Doelman C,Duijm LE,Liem YS,et al.Stenosis detection in fail-ing hemodialysis access fistulas and grafts:Comparison of colorDoppler ultrasonography,contrast-enhanced magnetic resonanceangiography,and digital subtraction angiography.J Vasc Surg,2005,42(4):739-746.
  • 4Heye S,Maleux G,Claes K,et al.Stenosis detection in nativehemodialysis fistulas with MDCT angiography.AJR Am J Roent-genol,2009,192(4):1079-1084.
  • 5Froger CL,Duijm LE,Liem YS,et al.Stenosis detection withMR angiography and digital subtraction angiography in dysfunc-tional hemodialysis access fistulas and grafts.Radiology,2005,234(1):284-291.
  • 6Heye S,Maleux G,Claes K,et al.Magnetic resonance tech-niques in hemodialysis access management.J Vasc Access,2003,4(4):125-139.
  • 7Zhang JB,Hecht EM,Maldonado T,et al.Time-resolved 3DMR angiography with parallel imaging for evaluation of hemodial-ysis fistulas and grafts:Initial experience.AJR Am J Roentgen-ol,2006,186(5):1436-1442.
  • 8Han KM,Duijm LE,Thelissen GR,et al.Failing hemodialysisaccess grafts:Evaluation of complete vascular tree with 3Dcon-trast-enhanced MR angiography with high spatial resolution:Ini-tial results in 10patients.Radiology,2003,227(2):601-605.
  • 9Pinto C,Hickey R,Carroll TJ.et al.Time-resolved MR angi-ography with generalized autocalibrating partially parallel acqui-sition and time-resolved echo-sharing angiographic technique forhemodialysis arteriovenous fistulas and grafts.J Vasc Interv Ra-diol,2006,17(6):1003-1009.
  • 10Mende KA,Froehlich JM,von Weymarn C,et al.Time-re-solved,high-resolution contrast-enhanced MR angiography of di-alysis shunts using the CENTRA keyhole technique with parallelimaging.J Magn Reson Imaging,2007,25(4):832-840.

引证文献5

二级引证文献26

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部