摘要 5 MW供热堆使用水力步进式驱动系统作为控制棒驱动系统.它是一种不同于压水堆使用的电磁-机械式传动的一种全新的控制棒传动。它以反应堆冷却剂(水)为工作介质,经泵加压后,注入安装在压力壳内的水力步进缸。通过由电磁阀组成的控制单元,控制注入步进缸的流量,使缸外套作步进运动,拖动中子吸收元件;控制核反应的进行。整个系统包括有13套传动缸及其控制单元,所有的控制单元集成到两个组合阀体上。 The hydraulic step driving system is used for driving of control rods on the 5 MW DHR. The system is based on a new concept of control rod driving, which is different from electric-magnetic-mechanic driving used for PWR. The reactor coolant (water) is used as actuating medium, pressed by pump, and then injected into hydraulic step cylinders which are set in the reactor vessel. The outer tube of the cylinder will be moving step by step by controlling flow, driving the neutron absorber and controlling nuclear reaction. 5 MW DHR is the first reactor in the world, in which the hydraulic driving system was used. Using the system is for getting better safety, reliability and economy. The principle of hydraulic step driving, the design and experimental research of ,the system are described in the paper.
机构地区 核能技术研究所
出处 《清华大学学报(自然科学版)》 EI CAS CSCD 北大核心 1990年第6期53-59,共7页 Journal of Tsinghua University(Science and Technology)
关键词 供热堆 控制棒 水力驱动系统 hydraulic step cylinder, limit injection, combined value
  • 相关文献

参考文献3

  • 1团体著者,1989年
  • 2匿名著者,核反应堆控制机构设计基础,1982年
  • 3团体著者,机械工程手册,1980年

同被引文献21

  • 1田嘉夫,杨富.低温核能供热经济分析[J].核动力工程,1994,15(6):512-516. 被引量:5
  • 2薄涵亮 迟宗波.200MW低温堆水力控制棒驱动系统综合性能实验和寿命考验[M].清华大学核能技术设计研究院内部报告,1998..
  • 3陈国飞.水力步进缸控制棒驱动系统温度特性的研究[硕士论文].清华大学,1990,6..
  • 4薄涵亮 迟宗波 等.200MW低温核供热堆水力驱动控制棒系统综合性能实验与寿命考验[M].北京:清华大学核能技术设计研究院,1998..
  • 5薄涵亮 刘志勇 等.水力驱动控制棒极限落棒能力实验研究[M].北京:清华大学核能技术设计研究院,2001..
  • 6江宏俊.流体力学[M].西安:西安交通大学出版社,1982..
  • 7薄涵亮 张佑杰 等.200MW供热堆水力驱动控制棒系统试验台架控制与测量系统[M].北京:清华大学核能技术设计研究院,1998..
  • 8吴元强,清华大学学报,1990年,30卷,6期
  • 9陈国飞,硕士学位论文,1990年
  • 10薄涵亮,清华大学核能技术设计研究院内部报告,1998年