摘要 目的:用电化学交流阻抗谱方法研究钴铬、镍铬合金和纯钛在人工唾液中的耐腐蚀性。方法:用电化学工作站测量出3种金属材料在人工唾液中的电化学阻抗谱(Bode图、Nyquist图),利用ZSimpWin软件对数据进行拟合分析,根据等效电路R(CR)拟合结果来评估3种金属的耐腐蚀性能。结果:从Nyquist图可见,3种材料的容抗弧半径大小依次为纯钛>钴铬合金>镍铬合金;从Bode图见,3种材料均为一个时间常数,即表面均是一个电容层。根据等效电路R(CR),3种材料的电容层无明显区别,但三者的阻抗值均很大,其中纯钛的阻抗值最大,钴铬合金的阻抗值居中,镍铬合金的阻抗值最小。结论:3种材料在人工唾液中均具有良好的耐腐蚀性,其耐腐蚀性能顺序是纯钛>钴铬合金>镍铬合金。 PURPOSE:With the help of electrochemical impedance spectroscopy (EIS),the purpose of the study was to investigate the corrosion resistance of CoCr alloys ,NiCr alloys and commercially pure Ti(cp Ti) in the artificial saliva(AS). METHODS:With the EIS,a test was made on the three alloys/metals in the AS (See Bode plot and Nyquist plot). And then,an analysis was made on what was known in the test by the software of ZSimpWin,after which the corrosion resistance of the alloys/metals was evaluated against the parameters of equivalent circuit [R (CR)]. RESULTS:In the Nyquist plot,the capacitance arc radius was in the sequence of cp Ti〉CoCrNi〉Cr. From the Bode plot,an one time constant was able to be obtained. That was the capacitor layer. According to the equivalent circuit[R(CR)],there was no significant difference in the capacitor layer of the three alloys/metals. And the sequence of the impedance value of the three alloys/metals was cp Ti〉CoCrNi〉Cr. CONCLUSIONS:The EIS results suggest that the three alloys/metals have a great corrosion resistance with cp Ti having the highest corrosion resistance and that CoCr alloys is better than NiCr alloys in the corrosion resistance.
出处 《上海口腔医学》 CAS CSCD 2010年第2期168-172,共5页 Shanghai Journal of Stomatology
基金 上海市科学技术委员会资助项目(08DZ2271100) 上海市重点学科建设项目(T0202)~~
关键词 镍铬合金 钴铬合金 电化学交流阻抗谱 等效电路 耐腐蚀性 CoCr alloy NiCr alloy Titanium Electrochemical impedance spectroscopy Equivalent circuit Corrosion resistance
  • 相关文献

参考文献18

  • 1Wataha JC. Biocompatibility of dental casting alloys: A review [J]. J Prosthet Dent, 2000,83(2):223-234.
  • 2Lu Y, Chen W, Ke W, et al.Nickel-based (Ni-Cr and Ni-Cr-Be) alloys used in dental restorations may be a potential cause for immune-mediated hypersensitivity[J]. Med Hypotheses,2009,73(5): 716-717.
  • 3Rincic N, Baucic I, Miko S, et al. Corrosion behaviour of the Co- Cr-Mo dental alloy in solutions of different composition and different pH values[J]. Coll Antropol, 2003,27 (Suppl 2):99-106.
  • 4Chang JC, Oshida Y, Gregory RL,et al. Electrochemical study on microbiology-related corrosion of metallic dental materials [J]. Biomed Mater Eng, 2003,13(3):281-295.
  • 5Bayramoglu G, Alemdaroglu T, Kedici S, et al. The effect of pH on the corrosion of dental metal alloys[J]. J Oral Rehabil, 2000,27 (7):563-575.
  • 6Laurent F, Grosgogeat B, Reclam L, et al. Comparison of corrosion behaviour in presence of oral bacteria[J]. Biomaterials, 2001, 22(16):2273-2282.
  • 7崔晓莉,江志裕.交流阻抗谱的表示及应用[J].上海师范大学学报(自然科学版),2001,30(4):53-61. 被引量:66
  • 8孙占梅,王彪,陈金富.金属材料在醋酸中的腐蚀行为研究[J].腐蚀与防护,1998,19(2):55-58. 被引量:14
  • 9Slemnik M, Milosev I. An impedance study of two types of stainless steel in Ringer physiological solution containing complexing agents[J]. J Mater Sci Mater Med, 2006,17(10):911-918.
  • 10Lin HY, Bowers B, Wolan JT, et al. Metallurgical, surface, and corrosion analysis of Ni-Cr dental casting alloys before and after porcelain firing[J]. Dent Mater, 2008,24(3):378-385.

二级参考文献23

  • 1周伟舫.电化学测量[M].上海:上海科学技术出版社,1983..
  • 2Model 398 Electrochemical Impedance Software User′s Guide[M]. EG&G Instruments Corporation Princeton Applied Research 1993, NJ USA, 121-126.
  • 3[英]南安普顿电化学小组,柳厚田,徐品第.电化学中的仪器方法[M].上海:复旦大学出版社,1992.
  • 4CONWAY B E, J. O′M BOCKRIS, RALPH E WHITE, ANDRZEJ LASIA, et al. Modern Aspects of Electrochemistry, Electrochemical Impedance Spectroscopy and Its Applications[M]. Kluwer Academic/Plenum Publishers, New York, 1999, 143-248.
  • 5JANEK R P, FAWCETT W R, ULMAN A. Impedance Spectroscopy of Self-assembled Monolayers on Au (111): Sodium Ferrocecyanide Charge Transfer at Modified Electrodes[J]. Langmuir, 1998, 14: 3011-3018.
  • 6HANS G L C, TERRY C C, ADELLE C F C. Impedance Spectroscopy of Interfaces, Membranes and Ultrastructures[J]. Bioelectrochem. Bioenerg. 1996,20:79-98.
  • 7AMEMIYA T, HASHIMOTO K, FUJISHIMA A. Faradaic Charge Transfer with Double-layer Charging and/or Adsorption-related Charging at Polmer-modified Electrodes as Observed by Color Impedance Spectroscopy[J]. J Phys Chem, 1993, 97(38): 9736-9740.
  • 8RUBINSTEIN I, SABATANI E, RISHPON J. Electrochemical Impedance Analysis of Polyaniline Films on Electrodes[J]. J Electrochem Soc, 1987, 134(12): 3078-3083.
  • 9BANDYOPADHYAY K, VIJAYAMOHANAN K, VENKATARAMANAN M, PRADEEP T. Self-assembled Monolayers of Small Aromatic Disulfide and Diselenide Molecules on Polycrystalline Gold Films: a Comparative Study of the Geometrical Constraint Using Temperature-dependent Surface-enhanced Raman Spectroscopy, X-ray Photoelectron Spectroscopy, and Electrochemistry[J]. Langmuir, 1999, 15: 5314-5322.
  • 10Ameer M A,Fekry A M,Heakal F El-Taib.Electrochemical behaviour of passive films on molybdenum -containing austenitic stainless steels in aqueous solutions[J].Electrochim.Acta,2004,50(1):43-49

共引文献93

同被引文献83

引证文献6

二级引证文献35

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部