摘要
应用静态挂片试验研究了高频电磁在处理水中的阻垢作用,讨论了电压、水中钙镁离子总浓度、pH、处理后放置时间及Ca2+/Mg2+比值等因素对阻垢效率的影响,并分析了其阻垢机理。结果表明,电压、水中钙镁离子总浓度、pH、处理后放置时间及Ca2+/Mg2+比值等因素对电子水处理器的阻垢效率的影响不同。当水加热时,水中盐类在显微镜下观察到点状结晶比杆状结晶多,同时其结晶总数亦明显增多。
The high-frequency electromagnetic field water treatment function for anti-scales using static slices is investigated. In static system, the affections of the voltage, total Ca^2+ and Mg^2+ concentration in water, pH value and Ca^2+/Mg^2+ to anti-scales are discussed and its anti-scales mechanism is analyzed. The result shows that there are different influence of the voltage, total Ca^2+ and Mg^2+ concentration in water, pH value and Ca^2+/Mg^2+ to anti-scales. In optical microscopy, the numbers of crystals of spot are more than those of rod and the same situation to the amount.