建筑围护结构热湿耦合传递特性实验研究与分析 被引量:16

Experimental Study of Coupled Heat and Moisture Transfer Performance through Building Envelope
在线阅读 下载PDF
导出
摘要 建立了多层墙体热湿耦合传递的实验测试方法,测试了长沙地区1月份和7月份空调房间外墙体内的温湿度分布情况.分析了热湿气候地区墙体内湿传递和积累的情况,以及不同内表面情况对墙体热湿性能的影响.实验结果表明:靠近室外侧水泥砂浆与红砖界面处的温度、湿度严重受室外温、湿度变化的影响,且此界面处的湿度长期高于80%,易引发霉菌的生长;靠近室内侧红砖与水泥抹灰界面处的温度、湿度主要受室内温、湿度的影响,变化较小;在夏季,内表面贴发泡塑料墙纸的墙体内各界面处的温、湿度普遍比没贴墙纸的墙体内相应位置处的要高;在冬季,两墙体内界面处的温度基本相同,但没贴墙纸的墙体内各界面处的湿度比内表面贴有发泡塑料墙纸的墙体要略高.同时,墙体内的温、湿度变化存在着很强的耦合作用,并且太阳辐射强度对墙体内的温、湿度分布有很大的影响. An experiment method was developed to test hygrothermal transfer performance through multilayer wall. The temperature and relative humidity was measured in the external walls of an air-conditioned room in Changsha in January and July. The moisture accumulation and transfer within the walls exposed to hot and humid climates were analyzed, and different inside wall treatments impact on the hygro- thermal performance of multilayer wall was also discussed. The results indicated that the temperature and humidity at the interface between the cement mortar and red brick were seriously affected by the changes of outdoor temperature and humidity, and the relative humidity of this interface was higher than 80 percent for a long-term. This can easily trigger the growth of mold; the temperature and the humidity at the interface between the red brick and cement plastering had small changes; they were affected by the changes of indoor temperature and humidity; in summer, the temperature and the humidity at the interface of the wall on the interior surface with the treatment of foam plastic wallpaper were generally higher than those of the wall on the inner surface with no treatment; and in winter, the temperature at the interface of two walls was basically the same, but the humidity at the interface of the wall that have no treatment was slightly higher than that of the wall on the interior surface with the treatment of foam plastic wallpaper. At the same time, the changes between temperature and humidity inside the wall coupled strongly, and solar radiation intensity had a great impact on the distribution of temperature and humidity inside the wall.
出处 《湖南大学学报(自然科学版)》 EI CAS CSCD 北大核心 2010年第4期11-16,共6页 Journal of Hunan University:Natural Sciences
基金 教育部高等学校博士学科点专项基金资助项目(20060532015)
关键词 建筑构件 热湿耦合传递 实验测试 围护结构 building components coupled heat and moisture transfer experiment and test building envelope
  • 相关文献

参考文献8

  • 1LOTZ W A.Moisture problems in buildings in hot humid climates[J].ASHRAE Journal,1989(4):26-27.
  • 2BAUGHMAN A X,ARENS E A.In door humidity and human health:part 1-literature review of health efects of humidity-influenced indoor pollutants[J].ASHRAE Transactions,1996,102(1):193-211.
  • 3郭兴国,陈友明.热湿气候地区多层墙体的热湿性能分析[J].湖南大学学报(自然科学版),2008,35(8):1-4. 被引量:10
  • 4TENWOLDE A.Steady-state one-dimensional water vapor movement by diffusion and convection in a multilayered wall[J].ASHRAE Transactions,1985,91(1A):322-342.
  • 5SHAKUN W.The causes and control of mold and mildew in hot and humid climates[J].ASHRAE Transactions,1996,102(92):128-129.
  • 6HOSNI M H,SIPES J M,WALLIS M H.Experimental results for diffusion and infiltration of moisture in concrete masonry walls exposed to hot and humid climates[J].ASHRAE Transactions,1999,105(2):191-203.
  • 7苏向辉.多层多孔结构内热湿耦合迁移特性研究[D].南京:南京航空航天大学航空宇航学院,2003:69-73.
  • 8冉茂宇,袁炯炯.调湿材料吸放湿性能的测试方法[J].暖通空调,2006,36(4):10-16. 被引量:12

二级参考文献19

  • 1冉茂宇.封闭空间蓄热体对室内空气温湿度调节性能[J].华侨大学学报(自然科学版),2004,25(4):396-400. 被引量:7
  • 2冯乃谦,李桂芝,邢锋.调湿材料的研究[J].新型建筑材料,1994,21(6):16-19. 被引量:21
  • 3渡村信治,前田雅喜.多孔セラミックスによゐ調濕材料の開発[J].機能材料,1997,17(2):22-24
  • 4松本衛.建築壁體におけゐ熱、水分同時移動および水分蓄積関すゐ研究[D].京都:京都大学,1978
  • 5尾崎明仁.建築壁體の熱、濕気移動解析[J].伝熱研究,1997,36(140):57-66.
  • 6WATERS J R, WRIGHT A J. Criteria for the distribution of nodes in multilayer walls in finite-difference thermal modeling[J]. Building and Environment, 1985,20 (3) : 51 - 62.
  • 7SHOUP T E. Numerical methods for the personal computer[M]. New Jersey: Prentice-Hall, Inc, 1983.
  • 8LIESEN R J, PEDERSEN C O. Modeling the energy effects of combined heat and mass transfer in building elements: part2-application to a building energy analysis program and examplea[J]. ASHRAE Transactions, 1999,105(2) : 954 - 961.
  • 9American Hotel and Motel Association. Mold and mildew in hotel and motel vip rooms in hot and humid climates[R]. Washington, DC: Hospitality Lodging & Travel Research Foundation, 1991.
  • 10KERESTECIOGLUE A, SWAMA M, KAMEL A. Theoretical and computational investigation of simultaneous heat and moisture transfer in buildings: “effective penetration depth” theory [ J ]. ASHRAE Transactions, 1990, 96 (1) :447 - 453.

共引文献22

同被引文献107

引证文献16

二级引证文献49

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部