摘要
研究了用反相HPLC测定甲萘威及其游离酚的方法。该方法的标准偏差为:甲萘威:019;1萘酚:00016;2萘酚:00005,回收率为:甲萘威:9839%~10182%;游离酚:9782%~100.15%。
The contents of carbaryl and free naphthol were determined by reverse HPLC with ODS=C18 reversed phase column and the mixture of methanol and water as mobile phase. The standard deviations in analysis of carbaryl, 1-naphthol and 2-naphthol were 0.19, 0.0016 and 0.0005, and the recoveries of carbaryl and free naphthol were 98.39%~101.82% and 97.82%~100.15%, respectively.