摘要
本文论述了对高压晶闸管阀的阀体空气间隙、绝缘件绝缘爬距和冷却水管电位分布的要求,指出了舟山直流输电工程采用的KGGS—100/500型高压晶闸管阀的绝缘缺陷,提出了改进意见,并介绍了改善后的效果。
This paper demonstrates the requirements for air-gap clearances in the valve, for insulating creepage distances of the insulating material and for electric potential distribution of the cooling water tub in the high voltage thyristor valve The insulation defects of type KGGS—100/500HV thyristor valve used in Zhou Shan HVDC Transmission project, are discussed.
出处
《高电压技术》
EI
CAS
CSCD
北大核心
1989年第1期20-24,共5页
High Voltage Engineering