期刊文献+

多层CT血管成像与数字减影血管造影诊断颅内微小动脉瘤的比较 被引量:15

Comparative study between multi-slice CT angiography and digital subtraction angiography in detection of intracranial miero-aneurysms
原文传递
导出
摘要 目的探讨MSCTA对最大径≤3mm颅内微小动脉瘤(IMA)的诊断价值。方法回顾性分析连续826例可疑颅内动脉瘤患者的临床和影像资料。全部患者住院前(发病后2h-4d)均采用16层螺旋CT行MSCTA,全部颅内动脉瘤均经DSA、三维旋转数字减影血管造影(3DRA)或手术证实。MSCTA、DSA及3DRA等影像资料由2名放射科医师独立进行分析。以DSA或3DRA为标准,计算MSCTA诊断IMA的敏感性、特异性及准确度,采用Kappa分析,评价DSA或3DRA与MSCTA两种检查方法诊断颅内IMA的一致性。采用χ2检验分析IMA与非IMA患者多发动脉瘤的患病率。结果826例可疑颅内动脉瘤患者中,788例为颅内动脉瘤患者,单发706例,多发82例,共发现889个动脉瘤,38例MSCTA、DSA或3DRA检查结果均为阴性。经DSA或3DRA检查证实,212例患者(271个动脉瘤)共有232个IMA。MSCTA检出229个IMA,假阳性1例,漏诊4个。以DSA或3DRA为标准,MSCTA诊断IMA的敏感性、特异性、准确度分别为98.3%(228/232)、97.4%(38/39)、98.2%(266/271)。两种检查方法有较强的一致性(Kappa值为0.927,P〈0.05)。IMA与非IMA患者多发动脉瘤患病率分别为21.2%(45/212)、6.4%(37/576),差异有统计学意义(χ2=36.421,P〈0.01)。结论MSCTA诊断IMA具有较高价值,鉴于MSCTA对IMA的检出达到≤3mm水准,提出将颅内IMA影像大小界定从4~5mm调整为≤3mm。 Objective To investigate the value of multi-slice computed tomography angiography (MSCTA) in the detection of intracranial micro-aneurysms ( aneurysm≤ 3 mm in maximal diameter, IMA). Methods The clinical history and images of 826 patients with suspected intracranial aneurysms were retrospectively analyzed. All patients underwent MSCTA on 16-slice row CT before hospitalization( from 2 h to 4 d after symtom onset). All intracranial aneurysms were confirmed by digital subtraction angiography (DSA), three-dimensional rotational angiography (3DRA) or surgery. Two independent radiologists assessed all the images. The MSCTA findings were compared with the DSA/3DRA results. The sensitivity, specificity, and accuracy of MSCTA for diagnosis of IMA was calculated. The diagnostic consistency between DSA/3DRA and MSCTA was determined by Kappa statistics. The prevalence of multiple aneurysms between the group of patients with IMA and the group of patients without IMA was evaluated by Chi-square test. Results A total of 889 aneurysms in 788 of the 826 patients were detected. Among them, 706 patients had single aneurysm and 82 patients had multiple aneurysms. No aneurysms were detected in 38 patients. Among the 212 patients who underwent DSA/3DRA, 271 aneurysms were found and 232 were IMA. MSCTA detected 229 IMA. There was 1 false-positive finding and g false-negative findings by MSCTA. The sensitivity, specificity and accuracy of MSCTA for IMA was 98. 3% (228/232) , 97.4% (38/39), 98. 2% (266/271). There was excellent agreement between two techniques(Kappa = 0.927,P 〈 0.05). The prevalence of multiple aneurysms was 21.2% (45/212) in the patient group with IMA and 6. 4% (37/576) in the group without IMA. There was statistically significant difference between the two groups ( χ2 = 36. 421 ,P 〈0. 01 ). Conehtsions The detection value of IMA by MSCTA was high. The cutoff level of diameter of intracranial IMA should be adjusted from 4-5 mm to≤3 mm.
出处 《中华放射学杂志》 CAS CSCD 北大核心 2010年第3期229-233,共5页 Chinese Journal of Radiology
基金 “十一五”国家科技部科技支撑计划重点项目(2007BA105807) 温州科技对外合作项目(H20090012) 温州市科技计划项目(Y20090005)
关键词 颅内动脉瘤 体层摄影术 X线计算机 蛛网膜下腔出血 Intracranial aneurysm Tomography,X-ray computed Subarachnoid hemorrhage
  • 相关文献

参考文献11

  • 1Romijn M, Gratama van Andel HA, van Walderveen MA, et al. Diagnostic accuracy of CT angiography with matched mask bone elimination for detection of intracranial aneurysms: comparison with digital subtraction angiography and 3D rotational angiography. AJNR ,2008,29 : 134-139.
  • 2McKinney AM, Palmer CS, Truwit CL, et al. Detection of aneurysms by 64-section multidetector CT angiography in patients acutely suspected of having an intracranial aneurysm and comparison with digital subtraction and 3D rotational angiography. AJNR, 2008,29:594-602.
  • 3朱玉森,李松柏,韩敏,李双玲,王强,徐克,刘云会,程鹏.多层面螺旋CT三维血管造影诊断脑动脉瘤临床价值的初步探讨[J].中华放射学杂志,2001,35(10):755-758. 被引量:99
  • 4陈伟建,杨运俊,王勇,钟鸣,谭显西,诸葛启钏.颅内动脉瘤破裂急性期三维CT血管造影的临床应用价值[J].中华急诊医学杂志,2006,15(11):996-1001. 被引量:24
  • 5Teksam M, McKinney A, Casey S, et al. Multi-section CT angiography for detection of cerebral aneurysms. AJNR ,2004,25 : 1485 -1492.
  • 6Dammert S, Krings T, Moller-Hartmann W, et al. Detection of intracranial aneurysms with multi-slice CT: comparison with conventional angiography. Neuroradiology, 2004, 46:427-434.
  • 7Yoon DY, Lim KJ, Choi CS, et al. Detection and characterization of intracranial aneurysms with 16-channel multi-detector row CT angiography: a prospective comparison of volume-rendered images and digital subtraction angiography. AJNR, 2007, 28:60-67.
  • 8Villablanca JP, Jahan R, Hooshi P, et al. Detection and characterization of very small cerebral aneurysms by using 2D and 3 D helical CT angiography. AJNR,2002, 23 : 1187-1198.
  • 9Sugahara T, Korogi Y, Nakashima K, et al . Comparison of 2D and 3D digital subtraction angiograpby in evaluation of intracranial aneurysms. AJNR, 2002, 23 : 1545-1552.
  • 10Matsumoto M, Sato M, Nakano M, et al. Three-dimensional computerized tomography angiography-guided surgery of acutely ruptured cerebral aneurysms. J Neurosurg,2001,94: 718-727.

二级参考文献13

共引文献120

同被引文献138

引证文献15

二级引证文献70

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部