期刊文献+

抑制冠状动脉内超声图像序列运动伪影的离线门控方法 被引量:4

An off-line gating method for suppressing motion artifacts in intracoronary ultrasound image sequence
原文传递
导出
摘要 针对连续回撤导管采集的、覆盖多个心动周期的冠状动脉内超声(ICUS)图像序列中存在的运动伪影问题,采用图像分析技术,对ICUS图像序列进行离线门控,从而改善ICUS纵向视图的视觉效果。首先,通过逐帧比较ICUS图像的灰度特征,构造ICUS序列的差异矩阵;然后,从差异矩阵中搜索出具有最小累计差异值的路径,为各帧找到其在相邻心动周期中的对应帧;最后,在滤波后的差异矩阵中,沿最优路径找到表示在各相邻心动周期舒张末期采集的图像对的点,得到最终的门控序列。对临床采集ICUS序列的实验验证了方法的可行性和精度。 To improve the longitudinal visualization and suppress the motion artifacts due to cyclic cardiac motion of continuous pullback intracoronary ultrasound(ICUS) image sequence covering several cardiac cycles, the cross-sectional ICUS image sequence is off-line gated with image analysis techniques. Firstly, a dissimilarity matrix is constructed through comparing intensity features of ICUS frames in a frame-by- frame manner. Then,an optimal path with the lowest cumulative dissimilarity value is found in the dissimilarity matrix, so that the optimal correspondence for each ICUS frame in successive cardiac cycles is obtained. Finally,in the filtered dissimilarity matrix, along the optimal path, those points denoting the frame pairs acquired at the end-diastole of each cardiac cycle are found to obtain the ultimate gated sequence. The validity and accuracy are demonstrated through experiments with clinical ICUS sequences.
作者 孙正
出处 《光电子.激光》 EI CAS CSCD 北大核心 2010年第4期632-638,共7页 Journal of Optoelectronics·Laser
基金 国家自然科学基金资助项目(30500129 60973087) 华北电力大学"211工程"3期校内面上资助项目
关键词 冠状动脉内超声(ICUS) 运动伪影 门控 图像特征 动态规划 intracoronary ultrasound(ICUS) motion artifact gating image property dynamic programming
  • 相关文献

参考文献19

  • 1林虹.血管内超声在冠状动脉疾病诊断及治疗中的应用[J].华夏医学,2006,19(3):617-619. 被引量:1
  • 2Bruining N,von Birgelen C,de Feyter PJ,et al. ECG-gated versus nongated three dimensional intracoronary ultrasound analysis: implications for volumetric measurements[J].Catheter Cardiovascular Diagnosis, 1998,43(3) : 254-260.
  • 3von Birgelen C, Mintz G, Nicosia A, et al. Electrocardiogramgated intravascular ultrasound image acquisition after coronary stent deployment facilitates on-line three dimensional reconstruction and automated lumen quantification[J]. JACC, 1997, 30(2) :436-443.
  • 4de Winter S A, Hamers R, Degertekin M, et al. A novel retrospective gating method for intracoronary ultrasound images based on image properties[A]. Proceedings of IEEE International Conference on Computers in Cardiology[C]. 2003,30: 13-16.
  • 5Carlo Gatta,Oriol Pujol,Oriol Rodriguez Leor,et al. Robust image based IVUS pullbacks gating[A]. Proceedings of 11th International Conference on Medical Image Computing and Computer-Assisted Intervention Part Ⅱ(MICCAI 2008)[C]. 2008, 5242.-518-525.
  • 6Zhu H,Oakeson K D,Friedman M H. Retrieval of cardiac phase from IVUS sequences[A]. Proceedings of SPIE Conference on Medical Imaging 2003 :Ultrasonic Imaging and Signal Processing[C].2003,5035 :135-146.
  • 7Barajas J,Caballero K L, Rodriguez O,et al. Cardiac phase extraction in IVUS sequences using 1-D gabor filters[A]. Proceedings of 29th Annual International Conference of the IEEE Engineering in Medicine and Biology Society (EMBS 2007) [C]. 2007:343-346.
  • 8Matsumoto M M S, Lemos P A, Yoneyama T, et al. Cardiac phase detection in Intravascular Ultrasound images [A]. Proceedings of SPIE Conference on Medical Imaging 2008 : Ultrasonic Imaging and Signal Processing[C]. 2008,6920: 69200D- 9.
  • 9Hernandez A, Rotger D, Gil D. Image-based ECG sampling of IVUS sequences[A]. Proceedings of 2008 IEEE International Ultrasonic Symposium (IUS)[C]. 2008, 1330-1333.
  • 10Nadkarni S K, Boughner D R, Fenster A. Image-based retrospective cardiac gating for three-dimensional intravascular ultrasound imaging[A]. Proceedings of SPIE Conference on Medical Imaging 2002 :Ultrasonic Imaging and Signal Processing[C]. 2002,4687 : 276-284.

二级参考文献37

  • 1郁道银,黄家祥,陈晓冬,孙正,谢洪波.基于B样条的冠状动脉树骨架三维重建方法[J].工程图学学报,2005,26(2):95-100. 被引量:5
  • 2孙正,郁道银,姜浩.基于变形模型的心血管三维运动跟踪[J].光电工程,2006,33(6):24-27. 被引量:6
  • 3孙正,郁道银,姜浩作.冠状动脉的三维运动特征提取[J].北京生物医学工程,2006,25(4):346-350. 被引量:1
  • 4胡春红,郁道银,孙正,陈晓冬.基于OpenGL的冠脉树在最佳视角下的投影显示[J].光电子.激光,2007,18(5):629-633. 被引量:2
  • 5GE J,ERBEL R,AMORANOL J,et al.Coronary artery remodeling in atherosclerotic disease:an intravascular ultrasonic study in vivo[J].Coron Artery Dis,1993,4:981-986.
  • 6PASTERKAMP G,WENSING P J,POST M J,et al.Paradoxi-calarterial wall shrinkage may contribute to luminal narrowing of human atherosclerotic femoral arteries[J].Circulation,1995,91:1444-1449.
  • 7VAMAVA A M,MILLS P G,DAVIES M J,et al.Relationship between coronary artery remodeling and plaque vulnerability[J].Circulation,2002,105:939-943.
  • 8DAVIES M J,RICHARDSON P D,WOOLF N,et al.Risk of thrombosis in human atherosclerotic plaques role of extracellular lipid,macrophag,and smooth muscle cell content[J].Br Heart J,1993,9:377-381.
  • 9SABATE M,KAY I P,D E FEYTER P J,et al.Remodeling of atherosclerotic coronary arteries varies in relation to location and composition of plaque[J].Am J Cardiol,1999,84:135-140.
  • 10PASTERKAMP G,SCHONEVELD A H.VAN DER WAL A C,et al.Relation of arterial geometry to luminal narrowing and histologic markers for plaque vulnerability:the remodeling paradox[J].J Am Coll Cardiol,1998,32:655-662.

共引文献3

同被引文献59

  • 1左明雪.人体解剖生理学[M].2版.北京:高等教育出版社,2009.
  • 2de Winter S A,Hamers R,Degertekin M. A novel retrospective gating method for intracoronary ultrasound images based on image properties[A].Kassandra Chalkidiki,Greece:IEEE Press,2003.13-16.
  • 3Hernàndez-Sabaté A,Gil D,Garcia-Barnés J. Image-based cardiac phase retrieval in intravascular ultrasound sequences[J].IEEE Transactions on Ultrasonics,Ferroelectrics,and Frequency Control,2011,(01):60-72.
  • 4Zhu H,Oakeson K D,Friedman M H. Retrieval of cardiac phase from IVUS sequences[A].Bellingham WA:SPIE Press,2003.135-146.
  • 5Nadkarni S K,Boughner D R,Fenster A. Image-based cardiac gating for three-dimensional intravascular ultrasound[J].Ultrasound in Medicine and Biology,2005,(01):53-63.doi:10.1016/j.ultrasmedbio.2004.08.025.
  • 6O'Malley S M,Granada J F,Carlier S. Image-based gating of intravascular ultrasound pullback sequences[J].IEEE Transactions on Information Technology in Biomedicine,2008,(03):299-306.
  • 7Carlo G,Oriol P,Oriol R L. Robust image-based IVUS pullbacks gating[A].New York City,USA:MICCAI Society Press,2008.518-525.
  • 8Danilouchkine M G,Mastik F,Steen A F W. Accuracy in prediction of catheter rotation in IVUS with feature-based optical flow-a phantom study[J].IEEE Transactions on Information Technology in Biomedicine,2008,(03):356-365.
  • 9Danilouchkine M G,Mastik F,Steen A F W. Two methods for catheter motion correction in IVUS palpography[A].New York NY:IEEE Press,2007.1724-1727.
  • 10Nadkami S K,Mills G,Boughner D R. A pulsating coronary vessel phantom for two-and threedimensional intravascular ultrasound studies[A].Utrecht,Netherlands:MICCAI Society Press,2001.1164-1165.

引证文献4

二级引证文献5

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部