摘要
针对施工图审查过程中发现的消防配电设计中经常出现的一些不妥做法,结合现行规范的有关规定,分析了这些做法的不足之处,并提出了消防配电的正确设计方法。
Aimed at a number of improper practices frequently occurred in the fire distribution design that were found during the construction drawing review process, combined with the relevant provisions of existing codes, the shortcomings of these practices are analyzed and the correct design methods of fire distribution are put forward.
出处
《建筑电气》
2010年第3期14-16,共3页
Building Electricity
关键词
短路保护
过负荷保护
消防配电线路
消防用电设备
Short- circuit protection Overloadprotection Fire distribution lines Fire consumer eqmpment