本文针对重庆2009年8月4日暴雨后,部分建筑强夯地基出现不同程度的不均匀沉降,讨论了强夯地基的遇水稳定性因素,并提出了确保强夯地基稳定的技术措施。
According to uneven settlement of dynamic consolidation foundation the under some buildings in different degree aider rainstorm in August 4, 2009 in Chongqing in this paper, we discussed stability factors of dynamic consolidation foundation aider rain, and proposed technical measures to ensure stability of dynamic consolidation foundation.